Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2004 Mar;13(2):311-20.
doi: 10.1023/B:QURE.0000018499.64574.1f.

Is a single-item visual analogue scale as valid, reliable and responsive as multi-item scales in measuring quality of life?

Affiliations
Comparative Study

Is a single-item visual analogue scale as valid, reliable and responsive as multi-item scales in measuring quality of life?

A G E M de Boer et al. Qual Life Res. 2004 Mar.

Abstract

Purpose: To compare the validity, reliability and responsiveness of a single, global quality of life question to multi-item scales.

Method: Data were obtained from 83 consecutive patients with oesophageal adenocarcinoma undergoing either transhiatal or transthoracic oesophagectomy. Quality of life was measured at baseline, 5 weeks, 3 and 12 months post-operatively with a single-item Visual Analogue Scale (VAS) ranging from 0 to 100, the multi-item Medical Outcomes Study Short Form-20 (MOS SF-20) and Rotterdam Symptom Check-List (RSCL). Convergent and discriminant validity, test-retest reliability and both distribution-based and anchor-based responsiveness were evaluated.

Major findings: At baseline and at 5 weeks, the VAS showed high correlations with the MOS SF-20 health perceptions scale (r = 0.70 and 0.72) and moderate to high correlations with all other subscales of the MOS SF-20 and RSCL (r = 0.29-0.70). The test-retest reliability intra-class correlation for the VAS was 0.87. At 5 weeks post-operatively, the distribution-based responsiveness was moderate for the VAS (standardised response mean: -0.47; effect size: -0.56), high for the physical subscales of the MOS SF-20 and RSCL (-1.08 to -1.51) and low for the psychological subscales (0.11 to -0.25). Five weeks post-operatively, anchor-based responsiveness was highest for the VAS (r = 0.54).

Conclusion: The VAS is an instrument with good validity, excellent reliability, moderate distribution-based responsiveness and good anchor-based responsiveness compared to multi-item questionnaires. Its use is recommended in clinical trials to assess global quality of life.

PubMed Disclaimer

References

    1. Br J Surg. 2001 May;88(5):643-52 - PubMed
    1. Br J Cancer. 1984 Jul;50(1):13-22 - PubMed
    1. JAMA. 1999 Sep 22-29;282(12):1157-62 - PubMed
    1. Health Serv Res. 1973 Fall;8(3):228-45 - PubMed
    1. Br J Surg. 2000 Jun;87(6):802-7 - PubMed

Publication types