Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2004 Apr;44(2):135-9.
doi: 10.1111/j.1479-828X.2004.00186.x.

Magnetic resonance imaging findings following three different vaginal vault prolapse repair procedures: a randomised study

Affiliations
Clinical Trial

Magnetic resonance imaging findings following three different vaginal vault prolapse repair procedures: a randomised study

Ajay Rane et al. Aust N Z J Obstet Gynaecol. 2004 Apr.

Abstract

Objective: To compare the vaginal configuration on magnetic resonance imaging following transvaginal sacrospinous fixation (SSF), posterior intravaginal slingplasty (PIVS) (infracoccygeal sacropexy) and sacrocolpopexy (SCP).

Materials and methods: Twenty-one patients with vault prolapse requiring surgical treatment were randomly assigned in a balanced way to undergo SSF (n = 7), PIVS (n = 7) or SCP (n = 7). The magnetic resonance imaging of the pelvis were performed preoperatively and at 6-12 weeks postoperatively to assess the vaginal configuration using the method described previously. The two main angles measured were: (i) the angle between the lower vagina and pubococcygeal line 'd-angle' (normal: 53 +/- 15 degrees ); and (ii) the angle between the lower and upper vagina planes 'e-angle' (normal: 145 +/- 7 degrees ).

Results: The mean preoperative/postoperatively measured d-angles were 69 degrees /62 degrees, 58 degrees /70 degrees, and 49 degrees /52 degrees for SSF, PIVS and SCP, respectively. The corresponding means for the e-angle were 173 degrees /215 degrees, 189 degrees /146 degrees, and 205 degrees /149 degrees. The changes of the e-angles proved to be statistically significant (P < 0.05) in each surgical group, while no significant change in the d-angle could be found in any of the three groups.

Conclusions: Significant improvements in the restoration of vaginal configuration were achieved in patients who underwent PIVS or SCP. Sacrospinous fixation in contrast seems to increase anatomical distortion of the vaginal configuration.

PubMed Disclaimer

LinkOut - more resources