Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2004 May;182(5):1217-23.
doi: 10.2214/ajr.182.5.1821217.

Comparison of superparamagnetic iron oxide-enhanced and gadobenate dimeglumine-enhanced dynamic MRI for detection of small hepatocellular carcinomas

Affiliations
Comparative Study

Comparison of superparamagnetic iron oxide-enhanced and gadobenate dimeglumine-enhanced dynamic MRI for detection of small hepatocellular carcinomas

Young Kon Kim et al. AJR Am J Roentgenol. 2004 May.

Abstract

Objective: The purpose of this study was to compare superparamagnetic iron oxide (SPIO)-enhanced MRI with gadobenate dimeglumine-enhanced MRI for the detection of hepatocellular carcinoma using receiver operating characteristic (ROC) analysis.

Materials and methods: Twenty-nine consecutive patients with 35 hepatocellular carcinomas underwent gadobenate dimeglumine-enhanced MRI (unenhanced, arterial, portal, and equilibrium phases) using 3D fat-saturated volumetric interpolated imaging and SPIO-enhanced MRI on a 1.5-T unit. SPIO-enhanced T2-weighted turbo spin-echo and T2*-weighted gradient-echo sequences were performed 48 hr after completion of the dynamic study. Three observers independently interpreted the images in random order, separately, and without patient identifiers. Diagnostic accuracy was evaluated using the alternative free response receiver operating characteristic method. Sensitivity and positive predictive value were also evaluated.

Results: The mean sensitivity and positive predictive value of SPIO-enhanced imaging were 81.0% and 85.0%, respectively, and those of gadobenate dimeglumine-enhanced MRI were 91.4% and 88.1%, respectively. A significant difference was seen in the sensitivity of the two MRI examinations (p < 0.05). The mean value of the area under the ROC curve (A(z)) for gadobenate dimeglumine-enhanced imaging (A(z) = 0.97 +/- 0.01) was significantly higher than that for SPIO-enhanced imaging (A(z) = 0.90 +/- 0.02) (p = 0.004).

Conclusion: Gadobenate dimeglumine-enhanced 3D dynamic imaging showed better diagnostic performance than SPIO-enhanced imaging for the detection of hepatocellular carcinomas.

PubMed Disclaimer

Publication types

LinkOut - more resources