Pulmonary artery thermodilution cardiac output vs. transpulmonary thermodilution cardiac output in two patients with intrathoracic pathology
- PMID: 15101866
- DOI: 10.1111/j.1399-6576.2004.00375.x
Pulmonary artery thermodilution cardiac output vs. transpulmonary thermodilution cardiac output in two patients with intrathoracic pathology
Abstract
In two adult patients, one with a severe hemorrhage and one with a partial anomalous pulmonary vein, cardiac output (CO) measurements were performed simultaneously by means of the bolus transpulmonary thermodilution technique (COao) and continuous pulmonary artery thermodilution method (CCOpa). In both cases, the methods revealed clinically significant different cardiac output values based upon the site of measurement and the underlying pathology. The assessment of cardiac output (CO) is considered an important part of cardiovascular monitoring of the critically ill patient. Cardiac output is most commonly determined intermittently by the bolus thermodilution technique with a pulmonary artery catheter (COpa). As continuous monitoring of CO is preferable to this intermittent technique, two major techniques have been proposed. Firstly, a nearly continuous thermodilution method (CCOpa) using a heating filament mounted on a pulmonary artery catheter (Baxter Edwards Laboratories, Irvine, CA), with a clinically acceptable accuracy compared with the intermittent bolus technique. Based on these results we assumed CCOpa equivalent to real CO during hemodynamically stable conditions, and secondly, a continuous cardiac output system based on pulse contour analysis (PCCO), such as the PiCCO system (Pulsion Medical System, Munchen, Germany). To calibrate this device, which uses a derivation of the algorithm of Wesseling and colleagues, an independently obtained value of CO by the transpulmonary thermodilution method (COao) is used. Clinical validation studies in patients without underlying intrathoracic pathology, comparing transpulmonary COao with the pulmonary technique (COpa), mostly yielded good agreement.
Similar articles
-
Measurement of cardiac output by transpulmonary arterial thermodilution using a long radial artery catheter. A comparison with intermittent pulmonary artery thermodilution.Anaesthesia. 2004 Jun;59(6):590-4. doi: 10.1111/j.1365-2044.2004.03710.x. Anaesthesia. 2004. PMID: 15144300
-
The level of cardiac output affects the relationship and agreement between pulmonary artery and transpulmonary aortic thermodilution measurements in an animal model.J Cardiothorac Vasc Anesth. 2007 Oct;21(5):659-63. doi: 10.1053/j.jvca.2007.01.005. Epub 2007 Apr 26. J Cardiothorac Vasc Anesth. 2007. PMID: 17905270
-
Comparison of FloTrac cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements.Eur J Anaesthesiol. 2007 Oct;24(10):832-9. doi: 10.1017/S0265021507001056. Epub 2007 Aug 1. Eur J Anaesthesiol. 2007. PMID: 17666154 Clinical Trial.
-
Hemodynamic monitoring by transpulmonary thermodilution and pulse contour analysis in critically ill children.Pediatr Crit Care Med. 2011 Jul;12(4):459-66. doi: 10.1097/PCC.0b013e3182070959. Pediatr Crit Care Med. 2011. PMID: 21263372 Review.
-
[Volumetric monitoring based on transpulmonary thermodilution in anesthesiology and intensive care].Anesteziol Reanimatol. 2003 Jul-Aug;(4):67-73. Anesteziol Reanimatol. 2003. PMID: 14524028 Review. Russian.
Cited by
-
Influence of extravascular lung water on transpulmonary thermodilution-derived cardiac output measurement.Intensive Care Med. 2008 Mar;34(3):533-7. doi: 10.1007/s00134-007-0916-4. Epub 2007 Nov 3. Intensive Care Med. 2008. PMID: 17982741
-
Methods in pharmacology: measurement of cardiac output.Br J Clin Pharmacol. 2011 Mar;71(3):316-30. doi: 10.1111/j.1365-2125.2010.03798.x. Br J Clin Pharmacol. 2011. PMID: 21284692 Free PMC article. Review.
-
Comparison of the accuracy of transpulmonary thermodilution measurement using indicators of different temperatures.Int J Clin Exp Med. 2014 Dec 15;7(12):5711-4. eCollection 2014. Int J Clin Exp Med. 2014. PMID: 25664096 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials