Recombinant Factor VIIa concentrate versus plasma derived concentrates for the treatment of acute bleeding episodes in people with Haemophilia A and inhibitors
- PMID: 15106253
- DOI: 10.1002/14651858.CD004449.pub2
Recombinant Factor VIIa concentrate versus plasma derived concentrates for the treatment of acute bleeding episodes in people with Haemophilia A and inhibitors
Update in
-
Recombinant Factor VIIa concentrate versus plasma derived concentrates for the treatment of acute bleeding episodes in people with haemophilia and inhibitors.Cochrane Database Syst Rev. 2010 Aug 4;(8):CD004449. doi: 10.1002/14651858.CD004449.pub3. Cochrane Database Syst Rev. 2010. Update in: Cochrane Database Syst Rev. 2015 Dec 16;(12):CD004449. doi: 10.1002/14651858.CD004449.pub4. PMID: 20687076 Updated.
Abstract
Background: In some people with haemophilia, therapeutic clotting agents are recognised as a foreign protein and anti-FVIII antibodies, known as 'inhibitors', are produced. This review investigates which treatment most effectively arrests acute bleeding in people with haemophilia A and inhibitors.
Objectives: To determine the clinical effectiveness of recombinant FVIIa concentrate in comparison to plasma-derived concentrates for the treatment of acute bleeding episodes in people with haemophilia A and inhibitors.
Search strategy: We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group trials register which comprises of references identified from comprehensive electronic database searches and handsearching of relevant journals and abstract books of conference proceedings. Date of the most recent search of the Group's trials register: September 2003.
Selection criteria: Randomised (RCTs) and quasi-randomised controlled clinical trials comparing Recombinant FVIIa concentrate to human plasma-derived concentrates (high-dose human or recombinant FVIII concentrate; prothrombin complex concentrates (PCCs); activated prothrombin complex concentrate (aPCC)) in people with haemophilia A. Comparisons with animal derived products were excluded.
Data collection and analysis: No studies were found that were eligible for inclusion in this review.
Main results: A total of four studies were identified by the searches, however, none of these were eligible for inclusion in this review.
Reviewers' conclusions: No RCTs on the relative effectiveness of Recombinant FVIIa concentrate compared to human plasma-derived concentrates in people with haemophilia A and inhibitors were identified for inclusion in this review. The research evidence on which to base clinical decisions is therefore limited to case reports, and other less robust evidence. There is need for a well-designed, adequately-powered randomised controlled trial to assess the relative benefits and risks of using Recombinant FVIIa concentrate compared to human plasma-derived concentrates in people with haemophilia A and inhibitors.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical