Abstract
Background: We report our initial experience with an automatic anastomotic device using skeletonized radial artery in patients requiring off-pump coronary artery bypass grafting (CABG).
Methods: St. Jude Medical, Inc, Symmetry Bypass System (aortic connector system [ACS]) (St Jude Medical, St. Paul, MN) was used in ten patients. Ten consecutive patients who underwent off-pump CABG and who received at least one radial artery graft proximal anastomosis using the ACS were evaluated. The radial artery (RA) was harvested in a skeletonized fashion and applied to the ACS in the same manner as applying saphenous vein graft. The creation of the anastomosis lasted no longer than a few seconds.
Results: Our attempt to use the ACS for proximal anastomosis of the RA was successful in all ten patients. Mean operating time was 3.2 +/- 0.6 minutes and an average of 3.0 +/- 0.9 bypass grafts (range, 2 to 5 grafts) were performed. There was no postoperative fatal complication. Postoperative angiographic control showed that all grafts were widely patent including grafts other than the RA. During the mean postoperative follow-up of 10.3 +/- 2.9 months, there was no cardiac-related event in any patient.
Conclusions: The St. Jude Medical Symmetry aortic connector system allows the construction of uniform and widely patent anastomoses in RA graft and does not require aortic side biting. Skeletonization of the RA is a safe and effective technique for applying ACS in off-pump CABG using multiple arterial grafts.
Similar articles
-
Use of skeletonized radial artery graft with the PAS-Port proximal anastomotic device.Ann Thorac Surg. 2009 Jun;87(6):1910-3. doi: 10.1016/j.athoracsur.2008.12.094. Ann Thorac Surg. 2009. PMID: 19463618
-
[Clinical experience with aortic connector system].Kyobu Geka. 2005 Feb;58(2):89-92; discussion 92-5. Kyobu Geka. 2005. PMID: 15724468 Japanese.
-
First clinical results with a new mechanical connector for distal coronary artery anastomoses in CABG.Circulation. 2002 Sep 24;106(12 Suppl 1):I1-4. Circulation. 2002. PMID: 12354699 Clinical Trial.
-
Radial artery bypass grafts have an increased occurrence of angiographically severe stenosis and occlusion compared with left internal mammary arteries and saphenous vein grafts.Circulation. 2004 May 4;109(17):2086-91. doi: 10.1161/01.CIR.0000127570.20508.5C. Circulation. 2004. PMID: 15123539 Review.
-
Role of radial artery graft in coronary artery bypass grafting.Ann Thorac Surg. 2005 Jun;79(6):2180-8. doi: 10.1016/j.athoracsur.2004.07.049. Ann Thorac Surg. 2005. PMID: 15919345 Review.
Cited by
-
Mid-term follow up of patients using the St. Jude Medical Aortic Connector System for proximal vein graft in CABG.J Korean Med Sci. 2006 Oct;21(5):849-53. doi: 10.3346/jkms.2006.21.5.849. J Korean Med Sci. 2006. PMID: 17043418 Free PMC article.
-
Skeletonization of radial and gastroepiploic conduits in coronary artery bypass surgery.J Cardiothorac Surg. 2007 Jun 5;2:26. doi: 10.1186/1749-8090-2-26. J Cardiothorac Surg. 2007. PMID: 17550580 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical