Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2004;93(1):52-6.
doi: 10.1177/145749690409300111.

Endovascular vs open AAA repair: similar effects on renal proximal tubular function

Affiliations
Comparative Study

Endovascular vs open AAA repair: similar effects on renal proximal tubular function

P S Aho et al. Scand J Surg. 2004.

Abstract

Aim: To compare the effect of open and endovascular repair on renal function.

Materials and methods: In a prospective, non-randomized study twenty-four abdominal aortic aneurysms (AAA) treatable with either method were repaired, 15 using endovascular device (ENDO group) and nine with open surgery with infrarenal aortic cross-clamping (OPEN group). All the patients had standardised general anaesthesia, intravascular fluid therapy and monitoring. Renal function tests and cardiovascular measurements were performed at predetermined intervals.

Results: N-acetyl-beta-D-glucosaminidase indexed to urinary creatinine (U-NAG/crea), a sensitive marker of renal proximal tubular damage, increased similarly in both groups at the end of surgery (two-way ANOVA, p < 0.05). No patient developed clinical renal impairment, on the contrary, creatinine clearance was increased, serum cystatin C (a sensitive marker of renal glomerular filtration) and serum creatinine concentration decreased at 24 hours postoperatively (Wilcoxon paired test, p < 0.05). Intraoperative blood loss and the amount of administered crystalloids were higher in the OPEN than in the ENDO group (Mann-Whitney U-test, p < 0.05). The cardiovascular measurements were comparable between the groups. The mean (SD) amount of radio-contrast media given was 3.1 (1.1) ml/kg in the ENDO group.

Conclusions: Our results indicate that endovascular AAA repair does not protect renal proximal tubular function. A temporary renal tubular dysfunction was found both in open and in endovascular AAA repair which did not lead to permanent changes in renal function.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources