Alarms based on real-time sensor glucose values alert patients to hypo- and hyperglycemia: the guardian continuous monitoring system
- PMID: 15117576
- DOI: 10.1089/152091504773731285
Alarms based on real-time sensor glucose values alert patients to hypo- and hyperglycemia: the guardian continuous monitoring system
Abstract
The purposes of this study were to demonstrate the accuracy and effectiveness of the Guardian Continuous Monitoring System (Medtronic MiniMed, Northridge, California) and to demonstrate that the application of real-time alarms to continuous monitoring alerts users to hypo and hyperglycemia and reduces excursions in people with diabetes. A total of 71 subjects with type 1 diabetes, mean hemoglobin A1c of 7.6 +/- 1.1%, age 44.0 +/- 11.4 years, and duration of diabetes 23.6 +/- 10.6 years were enrolled in this two-period, randomized, multicenter study. Subjects were randomized into either an Alert group or a Control group. The accuracy of the Guardian was evaluated by treating the study data as a single-sample correlational design. Effectiveness of the Guardian alerts was evaluated by comparing the Alert group with the Control group. The mean (median) absolute relative error between home blood glucose meter readings and sensor values was 21.3% (17.3%), and the Guardian, on average, read 12.8 mg/dL below the concurrent home blood glucose meter readings. The hypoglycemia alert was able to distinguished glucose values < or =70 mg/dL with 67% sensitivity, 90% specificity, and 47% false alerts. The hyperglycemia alert showed a similar ability to detect sensor values > or =250 mg/dL with 63% sensitivity, 97% specificity, and 19% false alerts. The Alert group demonstrated a median decrease in the duration of hypoglycemic excursions (-27.8 min) that was significantly greater than the median decrease in the duration of hypoglycemic excursions in the Control group (-4.5 min) (P = 0.03). A marginally significant increase in the frequency of hyperglycemic excursions (P = 0.07) between Period 1 and Period 2 was accompanied by a decrease of 9.6 min in the duration of hyperglycemic excursions in the Alert group. Glucose measurements differ between blood samples taken from the finger and interstitial fluid, especially when levels are changing rapidly; however, these results demonstrate that the Guardian is reasonably accurate while performing continuous glucose monitoring. The subjects' responses to hypoglycemia alerts resulted in a significant reduction in the duration of hypoglycemic excursions; however, overtreating hypoglycemia may have resulted in a marginally significant increase in the frequency of hyperglycemic excursions.
Comment in
-
The role of new technology in the early detection of hypoglycemia.Diabetes Technol Ther. 2004 Apr;6(2):115-7. doi: 10.1089/152091504773731294. Diabetes Technol Ther. 2004. PMID: 15117577 No abstract available.
Similar articles
-
Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: a randomized controlled trial.Diabetes Care. 2006 Jan;29(1):44-50. doi: 10.2337/diacare.29.01.06.dc05-1686. Diabetes Care. 2006. PMID: 16373894 Clinical Trial.
-
The Medtronic Minimed Gold continuous glucose monitoring system: an effective means to discover hypo- and hyperglycemia in children under 7 years of age.Diabetes Technol Ther. 2007 Aug;9(4):307-16. doi: 10.1089/dia.2007.0026. Diabetes Technol Ther. 2007. PMID: 17705686
-
Unrecognized hypo- and hyperglycemia in well-controlled patients with type 2 diabetes mellitus: the results of continuous glucose monitoring.Diabetes Technol Ther. 2003;5(1):19-26. doi: 10.1089/152091503763816427. Diabetes Technol Ther. 2003. PMID: 12725703
-
Hypo- and Hyperglycemic Alarms: Devices and Algorithms.J Diabetes Sci Technol. 2015 Apr 30;9(5):1126-37. doi: 10.1177/1932296815583507. J Diabetes Sci Technol. 2015. PMID: 25931581 Free PMC article. Review.
-
Real-time continuous glucose monitoring.Curr Opin Endocrinol Diabetes Obes. 2007 Aug;14(4):288-95. doi: 10.1097/MED.0b013e32825a675e. Curr Opin Endocrinol Diabetes Obes. 2007. PMID: 17940454 Review.
Cited by
-
Use of case-based reasoning to enhance intensive management of patients on insulin pump therapy.J Diabetes Sci Technol. 2008 Jul;2(4):603-11. doi: 10.1177/193229680800200411. J Diabetes Sci Technol. 2008. PMID: 19885236 Free PMC article.
-
"Smart" continuous glucose monitoring sensors: on-line signal processing issues.Sensors (Basel). 2010;10(7):6751-72. doi: 10.3390/s100706751. Epub 2010 Jul 12. Sensors (Basel). 2010. PMID: 22163574 Free PMC article. Review.
-
Artificial pancreas: past, present, future.Diabetes. 2011 Nov;60(11):2672-82. doi: 10.2337/db11-0654. Diabetes. 2011. PMID: 22025773 Free PMC article. Review. No abstract available.
-
Comparison of glucose monitoring methods during steady-state exercise in women.Nutrients. 2012 Sep;4(9):1282-92. doi: 10.3390/nu4091282. Epub 2012 Sep 14. Nutrients. 2012. PMID: 23112916 Free PMC article.
-
A review of current evidence with continuous glucose monitoring in patients with diabetes.J Diabetes Sci Technol. 2008 Jul;2(4):718-27. doi: 10.1177/193229680800200426. J Diabetes Sci Technol. 2008. PMID: 19885251 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical