Fibrin glue is useful in preventing early dialysate leakage in children on chronic peritoneal dialysis

Affiliations
  • PMID: 15119641
Clinical Trial

Fibrin glue is useful in preventing early dialysate leakage in children on chronic peritoneal dialysis

Ernesto T Sojo et al. Perit Dial Int. 2004 Mar-Apr.

Abstract

Objective: To assess if application of fibrin glue sealant to the peritoneal cuff suture is useful in the prevention of early dialysate leakage in children with end-stage renal disease on chronic peritoneal dialysis (CPD).

Design: Single-center, open-label, prospective randomized study.

Setting: University Pediatric Hospital.

Methods: 52 catheters were implanted in 45 children (mean age 6.2 +/- 4.5 years). Catheters were randomly assigned to either the control group or the sealant group. In the latter group, 1 mL of fibrin glue sealant was applied to the peritoneal cuff suture. 18 catheters were used for the first time within 5 days after implantation (early-used catheters). Leakage, exit-site or tunnel infection, peritonitis, and adverse secondary effects were evaluated during the initial 60 days after implantation.

Results: No adverse secondary effects were seen after the application of the fibrin glue sealant. The incidence of exit/tunnel infection and peritonitis was similar in the two groups. The incidence of leakage was significantly lower in the sealant group (p < 0.02). In the early-used catheters, leakage was detected in 9% of the catheters in the sealant group and in 57% of the control group (p < 0.05).

Conclusions: The application of 1 mL of fibrin glue to the peritoneal cuff suture prevented early dialysate leakage without secondary adverse effects in children on CPD.