Difficulty in advancing a tracheal tube over a fibreoptic bronchoscope: incidence, causes and solutions
- PMID: 15121723
- DOI: 10.1093/bja/aeh136
Difficulty in advancing a tracheal tube over a fibreoptic bronchoscope: incidence, causes and solutions
Comment in
-
Difficulty in advancing a tracheal tube over a fibreoptic bronchoscope: incidence, causes and solutions.Br J Anaesth. 2004 Dec;93(6):872. doi: 10.1093/bja/aeh632. Br J Anaesth. 2004. PMID: 15533957 No abstract available.
-
Difficulty in advancing a tracheal tube over a fibreoptic bronchoscope: more solutions.Br J Anaesth. 2005 Jul;95(1):112. doi: 10.1093/bja/aei570. Br J Anaesth. 2005. PMID: 15941739 No abstract available.
Similar articles
-
Difficulty in advancing a tracheal tube over a fibreoptic bronchoscope: incidence, causes and solutions.Br J Anaesth. 2004 Dec;93(6):872. doi: 10.1093/bja/aeh632. Br J Anaesth. 2004. PMID: 15533957 No abstract available.
-
Difficulty in advancing a tracheal tube over a fibreoptic bronchoscope: more solutions.Br J Anaesth. 2005 Jul;95(1):112. doi: 10.1093/bja/aei570. Br J Anaesth. 2005. PMID: 15941739 No abstract available.
-
Use of the laryngeal mask for fibrescope-aided tracheal intubation in an awake patient with a deviated larynx.Acta Anaesthesiol Scand. 1994 Aug;38(6):615-6. doi: 10.1111/j.1399-6576.1994.tb03962.x. Acta Anaesthesiol Scand. 1994. PMID: 7976155
-
[Tracheal intubation with Parker Flex-Tip tubes assisted by tube-guiding devices].Masui. 2010 Apr;59(4):432-9. Masui. 2010. PMID: 20420128 Review. Japanese.
-
Management strategies for the difficult pediatric airway.Middle East J Anaesthesiol. 2004 Jun;17(5):845-73. Middle East J Anaesthesiol. 2004. PMID: 15449744 Review. No abstract available.
Cited by
-
Anaesthetic and airway management of a post-burn contracture neck patient with microstomia and distorted nasal anatomy.Indian J Anaesth. 2014 Mar;58(2):210-3. doi: 10.4103/0019-5049.130834. Indian J Anaesth. 2014. PMID: 24963193 Free PMC article. No abstract available.
-
Successful endotracheal intubation with Trachway after failed fiber-optic manipulations in a patient with retropharyngeal cervical chordoma.Tzu Chi Med J. 2017 Jul-Sep;29(3):174-176. doi: 10.4103/tcmj.tcmj_63_17. Tzu Chi Med J. 2017. PMID: 28974913 Free PMC article.
-
Time to tracheal intubation over a fibreoptic bronchoscope using a silicone left double-lumen endobronchial tube versus polyvinyl chloride single-lumen tube with bronchial blocker: a randomized controlled non-inferiority trial.J Thorac Dis. 2019 Mar;11(3):901-908. doi: 10.21037/jtd.2019.01.108. J Thorac Dis. 2019. PMID: 31019779 Free PMC article.
-
Oral to Nasal Endotracheal Tube Exchange: Modification to Enable Wider Applicability of an "Old Connector" Technique-A Case Report.A A Pract. 2023 Jul 21;17(7):e01703. doi: 10.1213/XAA.0000000000001703. eCollection 2023 Jul 1. A A Pract. 2023. PMID: 37478059 Free PMC article.
-
Quest for an ideal intubating device.Oman Med J. 2012 Mar;27(2):175-6. doi: 10.5001/omj.2012.38. Oman Med J. 2012. PMID: 22496949 Free PMC article. No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical