Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2004 May 25;109(20):2423-7.
doi: 10.1161/01.CIR.0000129414.95137.CD. Epub 2004 May 3.

Neurological events during long-term mechanical circulatory support for heart failure: the Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) experience

Affiliations
Clinical Trial

Neurological events during long-term mechanical circulatory support for heart failure: the Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) experience

Ronald M Lazar et al. Circulation. .

Abstract

Background: Progression of heart failure can lead to cardiac transplantation, but when patients are ineligible, long-term mechanical circulatory support may improve survival. The REMATCH trial showed that left ventricular assist devices (LVADs) prolonged survival in patients with end-stage disease, but with a significant number of adverse events. We report on the neurological outcomes in the REMATCH trial.

Methods and results: We examined new neurological events in the 129 patients randomized to either LVAD placement (n=68) or medical management (n=61), classified as stroke, transient ischemic attack, toxic-metabolic encephalopathy, and other. There were 46 neurological events: 42 in 30 LVAD patients and 4 in 4 patients in the medical arm (chi2, 30/68 versus 4/61, P<0.001). Sixteen percent of the LVAD patients had a stroke, with a rate of 0.19 per year (95% CI, 0.10 to 0.33), many occurring in the postoperative period. The stroke rate in the medical arm was 0.052. A Kaplan-Meier survival analysis showed a 44% reduction in the risk of stroke or death in the LVAD group versus the optimal medical group (P=0.002). The mean interval from implantation to stroke was 221.8 days (+/-70.4 days). History of stroke, age, and sepsis were not stroke risk factors in the LVAD group.

Conclusions: Fewer than half of the patients in the LVAD group had a neurological event, and there were few neurological deaths. Survival analysis combining stroke or death demonstrated a significant benefit for long-term circulatory support with an LVAD over medical therapy. Future trials will need to address prospectively all neurological outcomes, including neurocognitive function, and the role of long-term neuroprotection.

PubMed Disclaimer

Publication types

MeSH terms