EUD-based margin selection in the presence of set-up uncertainties
- PMID: 15125003
- DOI: 10.1118/1.1668552
EUD-based margin selection in the presence of set-up uncertainties
Abstract
To assess the impact of geometric uncertainties on treatment plan design, we have performed a numerical simulation in which both systematic and random errors were included. A clinical target volume (CTV) with an abutting organ at risk (OAR), both of 50 mm diameter, in a cubic phantom was modeled. A four-field conformal treatment plan was designed in which one pair of parallel-opposed beams traversed the OAR and CTV while the other pair intersected the CTV only. Field size, prescribed (isocenter) dose and systematic set-up uncertainty were varied in two orthogonal directions to examine their impact on the outcome as predicted by the dose volume histogram (DVH) and the phenomenological form of equivalent uniform dose (EUD). Of the systematic uncertainty levels considered (0, 2, 4, and 6 mm standard deviations of a Gaussian distribution), 10 mm margin (CTV-PTV) was adequate to maintain the integrity of the dose distribution within the CTV. However, reducing the margin (and hence field size) without reducing set-up errors required an increase in the isocenter dose to compensate for the loss in EUD. It was found that, in the direction containing both the CTV and OAR, with random and systematic uncertainties of 2 and 4 mm respectively, increasing the isocenter dose by about 3.5 Gy on a 6 mm-margin plan resulted in the statistically equivalent EUD value to that with a 10 mm-margin for the CTV, while the OAR EUD is dropped by 1 Gy. In general, though, the directional sensitivity to geometric uncertainties, and hence the required margin size in different directions, was dependent on beam geometries and the relative positions of the structures under consideration relative to the beam directions. Based on the validity of the EUD concept, our general conclusion is that modest dose escalation may result in plans that better achieve clinical objectives. Also, a simple single number plan quality index such as EUD5%, discussed in the paper, facilitates meaningful statistical comparisons between competing treatment strategies.
Similar articles
-
The theoretical benefit of beam fringe compensation and field size reduction for iso-normal tissue complication probability dose escalation in radiotherapy of lung cancer.Med Phys. 2003 Jun;30(6):1086-95. doi: 10.1118/1.1573208. Med Phys. 2003. PMID: 12852532
-
A new method of incorporating systematic uncertainties in intensity-modulated radiotherapy optimization.Med Phys. 2005 Aug;32(8):2567-79. doi: 10.1118/1.1954161. Med Phys. 2005. PMID: 16193787
-
Coverage optimized planning: probabilistic treatment planning based on dose coverage histogram criteria.Med Phys. 2010 Feb;37(2):550-63. doi: 10.1118/1.3273063. Med Phys. 2010. PMID: 20229863 Free PMC article.
-
Managing geometric uncertainty in conformal intensity-modulated radiation therapy.Semin Radiat Oncol. 1999 Jan;9(1):4-19. doi: 10.1016/s1053-4296(99)80051-4. Semin Radiat Oncol. 1999. PMID: 10196395 Review.
-
In silico modelling of tumour margin diffusion and infiltration: review of current status.Comput Math Methods Med. 2012;2012:672895. doi: 10.1155/2012/672895. Epub 2012 Jul 11. Comput Math Methods Med. 2012. PMID: 22919432 Free PMC article. Review.
Cited by
-
Image quality & dosimetric property of an investigational imaging beam line MV-CBCT.J Appl Clin Med Phys. 2009 Jun 17;10(3):37-48. doi: 10.1120/jacmp.v10i3.3023. J Appl Clin Med Phys. 2009. PMID: 19692984 Free PMC article.
-
Evaluation of dosimetric margins in prostate IMRT treatment plans.Med Phys. 2008 Feb;35(2):569-75. doi: 10.1118/1.2826558. Med Phys. 2008. PMID: 18383678 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources