Determination of polyvinylpyrrolidone using high-performance liquid chromatography
- PMID: 15137988
- DOI: 10.1016/j.jpba.2004.01.024
Determination of polyvinylpyrrolidone using high-performance liquid chromatography
Abstract
Polyvinylpyrrolidone (PVP) is a versatile polymer with innate surface activity. It is very difficult to accurately assay due to its wide molecular weight range and amphiphilic nature. This study evaluated a reversed-phase HPLC method to separate and quantify PVP K15. The assay used a Hicrome C18 150 mm x 3 microm HPLC column in combination with an 80/20 propanol-1-ol: deionised water, 0.01% TFA mobile phase, which resolved the polymer as a single peak, tR = 10.69+/-0.17 min (n=120) at 243 nm. The column's performance was constant throughout the study, N (theoretical plates) = 1729+/-22 and the peak symmetry remained good (As ranged from 0.74 to 0.92, n=10 over the calibration range). The developed assay proved to be accurate, sensitive and capable of recovering PVP K15 from pharmaceutical formulations. The limits of quantification and detection were calculated statistically as 2.40 and 0.72 mg ml(-1), respectively. Assay reproducibility assessed at five concentrations gave an average coefficient of variance <3.5% and the accuracy of the analytical method was 102.62+/-2.04%. The recovery of PVP K15 from directly compressed tablets and Refresh eye drops was 98.02+/-2.73 and 108.35+/-6.52%, respectively.
Similar articles
-
C(18) columns for the simultaneous determination of oxytetracycline and its related substances by reversed-phase high performance liquid chromatography and UV detection.J Pharm Biomed Anal. 2007 Jan 17;43(2):506-14. doi: 10.1016/j.jpba.2006.07.048. Epub 2006 Sep 20. J Pharm Biomed Anal. 2007. PMID: 16989968
-
Quantitative determination of insulin entrapment efficiency in triblock copolymeric nanoparticles by high-performance liquid chromatography.J Pharm Biomed Anal. 2006 Apr 11;41(1):266-73. doi: 10.1016/j.jpba.2005.10.016. Epub 2005 Nov 21. J Pharm Biomed Anal. 2006. PMID: 16303273
-
Using of HPLC coupled with coulometric detector for the determination of biotin in pharmaceuticals.J Pharm Biomed Anal. 2007 Dec 21;45(5):730-5. doi: 10.1016/j.jpba.2007.08.010. Epub 2007 Aug 15. J Pharm Biomed Anal. 2007. PMID: 17920225
-
Use of high-performance liquid chromatography in the pharmaceutical industry.J Chromatogr. 1990 May 16;507:141-9. doi: 10.1016/s0021-9673(01)84189-3. J Chromatogr. 1990. PMID: 2199472 Review.
-
Nested designs in ruggedness testing.J Pharm Biomed Anal. 1999 Sep;20(6):875-87. doi: 10.1016/s0731-7085(99)00112-0. J Pharm Biomed Anal. 1999. PMID: 10746956 Review.
Cited by
-
Online Coupling of Lab-on-Valve Format to Amperometry Based on Polyvinylpyrrolidone-Doped Carbon Paste Electrode and Its Application to the Analysis of Morin.J Anal Methods Chem. 2012;2012:257109. doi: 10.1155/2012/257109. Epub 2012 Apr 5. J Anal Methods Chem. 2012. PMID: 22567551 Free PMC article.
-
Fluorescence quenching reaction of polyvinylpyrrolidone-eosin Y system for the determination of polyvinylpyrrolidone.J Fluoresc. 2010 May;20(3):733-8. doi: 10.1007/s10895-010-0615-3. Epub 2010 Mar 2. J Fluoresc. 2010. PMID: 20195711
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials