Manikin measurements versus wear trials of cold protective clothing (Subzero project)
- PMID: 15138839
- DOI: 10.1007/s00421-004-1139-9
Manikin measurements versus wear trials of cold protective clothing (Subzero project)
Abstract
The thermal insulation properties of clothing systems can be defined through physical measurements using thermal manikins or through wear trials using human test subjects. One objective of the European Subzero project was to define the relationship between physically measured thermal insulation values of cold-protective clothing and the corresponding physiological reactions on human test subjects. Four cold-protective clothing ensembles, intended for use in temperatures between 0 and -50 degrees C, were measured with manikins in eight European laboratories and on human test subjects in four of these laboratories. The results showed that reasonably good reproducible values from the manikin tests can be achieved (CV < 8%); however, the fit of the clothing on the manikin is a critical factor. There were greater individual differences in the wear trial results. Comparing the results from the manikin and the wear trials, good agreement in the thermal insulation values was shown if the amount of accumulated sweat was low. In these situations, which are normal when using cold protective clothing, the thermal comfort can also be determined with good accuracy by means of mathematical models based on manikin results. Special situations, e.g. for highly perspiring wearers, strong wind, or high friction between garment layers, need specific modelling; some suggestions have been made as a result of the Subzero project, but further research is required.
Similar articles
-
The influence of sweating on the heat transmission properties of cold protective clothing studied with a sweating thermal manikin.Int J Occup Saf Ergon. 2004;10(3):263-9. doi: 10.1080/10803548.2004.11076614. Int J Occup Saf Ergon. 2004. PMID: 15377411
-
Protection against cold in prehospital care: evaporative heat loss reduction by wet clothing removal or the addition of a vapor barrier--a thermal manikin study.Prehosp Disaster Med. 2012 Feb;27(1):53-8. doi: 10.1017/S1049023X12000210. Epub 2012 Mar 23. Prehosp Disaster Med. 2012. PMID: 22445055
-
Theoretical analysis of three methods for calculating thermal insulation of clothing from thermal manikin.Ann Occup Hyg. 2012 Jul;56(6):728-35. doi: 10.1093/annhyg/mer118. Ann Occup Hyg. 2012. PMID: 22798547
-
New functions and applications of walter, the sweating fabric manikin.Eur J Appl Physiol. 2004 Sep;92(6):641-4. doi: 10.1007/s00421-004-1134-1. Eur J Appl Physiol. 2004. PMID: 15138829 Review.
-
Recent trends in clothing physiology.Scand J Work Environ Health. 1989;15 Suppl 1:58-65. Scand J Work Environ Health. 1989. PMID: 2692141 Review.
Cited by
-
Non-evaporative effects of a wet mid layer on heat transfer through protective clothing.Eur J Appl Physiol. 2008 Sep;104(2):341-9. doi: 10.1007/s00421-007-0629-y. Epub 2007 Dec 15. Eur J Appl Physiol. 2008. PMID: 18084775
-
Effects of cooling and clothing on vertical trajectories of the upper arm and muscle functions during repetitive light work.Eur J Appl Physiol. 2008 Sep;104(2):183-91. doi: 10.1007/s00421-007-0657-7. Epub 2007 Dec 20. Eur J Appl Physiol. 2008. PMID: 18157725
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources