Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2004 Jun-Jul;85(2-3):407-31.
doi: 10.1016/j.pbiomolbio.2004.02.002.

Parameter estimation in cardiac ionic models

Affiliations
Free article
Comparative Study

Parameter estimation in cardiac ionic models

Socrates Dokos et al. Prog Biophys Mol Biol. 2004 Jun-Jul.
Free article

Abstract

We examine the problem of parameter estimation in mathematical models of excitable cell cardiac electrical activity using the well-known Beeler-Reuter (1977) ionic equations for the ventricular action potential. The estimation problem can be regarded as equivalent to the accurate reconstruction of ionic current kinetics and amplitudes in an excitable cell model, given only action potential experimental data. We show that in the Beeler-Reuter case, all ionic currents may be reasonably reconstructed using an experimental design consisting of action potential recordings perturbed by pseudo-random injection currents. The Beeler-Reuter model was parameterised into 63 parameters completely defining all membrane current amplitudes and kinetics. Total membrane current was fitted to model-generated experimental data using a 'data-clamp' protocol. The experimental data consisted of a default action-potential waveform and an optional series of perturbed waveforms generated by current injections. Local parameter identifiability was ascertained from the reciprocal condition value (1/lambda) of the Hessian at the known solution. When fitting to a single action potential waveform, the model was found to be over-determined, having a 1/lambda value of approximately 3.6e-14. This value improved slightly to approximately 1.4e-10 when an additional 2 perturbed waveforms were included in the fitting process, suggesting that the additional data did not overly improve the identifiability problem. The additional data, however, did allow the accurate reconstruction of all ionic currents. This indicates that by appropriate experimental design, it may be possible to infer the properties of underlying membrane currents from observation of transmembrane potential waveforms perturbed by pseudo-random currents.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources