AAPM/RSNA tutorial on equipment selection: PACS equipment overview: display systems
Abstract
Display systems are key components of the digital radiology department. Current display systems for medical imaging are based on cathode-ray tubes (CRTs) or active-matrix liquid crystal displays (AMLCDs). The CRT is a cathodoluminescent display: Light is generated by exciting a luminescent material with energetic electrons. AMLCDs are light-modulating devices that form the image in the screen by controlling the transparency of individual display pixels. Many image quality aspects of CRTs are determined by the way the pixel luminance is generated in the cathodoluminescent screen. The resolution properties of AMLCDs are much better than those of CRTs. In CRT devices, phosphor granularity and raster scanning patterns are the main components of spatial noise. In AMLCDs, the most notable feature of the noise characteristic is the subpixel structure of complex pixel designs used in medical displays. The small-spot contrast of CRTs is dominated mainly by veiling glare and reflections of ambient illumination. In addition to display reflectance, the contrast of medical AMLCDs is affected by crosstalk and by variations of the luminance at off-normal viewing angles.
Similar articles
-
Angular dependence of the luminance and contrast in medical monochrome liquid crystal displays.Med Phys. 2003 Oct;30(10):2602-13. doi: 10.1118/1.1606449. Med Phys. 2003. PMID: 14596296
-
Assessment of display performance for medical imaging systems: executive summary of AAPM TG18 report.Med Phys. 2005 Apr;32(4):1205-25. doi: 10.1118/1.1861159. Med Phys. 2005. PMID: 15895604
-
Active matrix liquid crystal displays for clinical imaging: comparison with cathode ray tube displays.J Digit Imaging. 2000 May;13(2 Suppl 1):155-61. doi: 10.1007/BF03167650. J Digit Imaging. 2000. PMID: 10847388 Free PMC article.
-
AAPM/RSNA tutorial on equipment selection: PACS equipment overview: general guidelines for purchasing and acceptance testing of PACS equipment.Radiographics. 2004 Jan-Feb;24(1):313-34. doi: 10.1148/rg.241035137. Radiographics. 2004. PMID: 14730055 Review.
-
High-fidelity electronic display of digital radiographs.Radiographics. 1999 Nov-Dec;19(6):1653-69. doi: 10.1148/radiographics.19.6.g99no081653. Radiographics. 1999. PMID: 10555680 Review.
Cited by
-
The influence of liquid crystal display (LCD) monitors on observer performance for the detection of nodular lesions on chest radiographs.Eur Radiol. 2006 Mar;16(3):726-32. doi: 10.1007/s00330-005-0030-3. Epub 2005 Nov 12. Eur Radiol. 2006. PMID: 16284772
-
Display Characteristics and Their Impact on Digital Pathology: A Current Review of Pathologists' Future "Microscope".J Pathol Inform. 2020 Aug 11;11:23. doi: 10.4103/jpi.jpi_38_20. eCollection 2020. J Pathol Inform. 2020. PMID: 33042602 Free PMC article. Review.
-
Influence of liquid crystal display monitors on observer performance for detection of diffuse pulmonary disease on chest radiographs.Radiat Med. 2007 Jun;25(5):211-7. doi: 10.1007/s11604-007-0126-6. Epub 2007 Jun 27. Radiat Med. 2007. PMID: 17581709
-
Detection of artificial occlusal caries in a phosphor imaging plate system with two types of LCD monitors versus three different films.J Digit Imaging. 2009 Jun;22(3):242-9. doi: 10.1007/s10278-008-9146-8. Epub 2008 Oct 24. J Digit Imaging. 2009. PMID: 18949518 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources