Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2004 Jun;25(6):1097-101.
doi: 10.1016/j.ejcts.2004.02.026.

Comparison of manual and mechanical cervical esophagogastric anastomosis after esophageal resection for squamous cell carcinoma: a prospective randomized controlled trial

Affiliations
Clinical Trial

Comparison of manual and mechanical cervical esophagogastric anastomosis after esophageal resection for squamous cell carcinoma: a prospective randomized controlled trial

Hsao-Hsun Hsu et al. Eur J Cardiothorac Surg. 2004 Jun.

Abstract

Objective: The use of a circular stapler in cervical esophagogastric anastomosis remains controversial. This study was to compare the postoperative and long-term results of manual and mechanical techniques for cervical esophagogastric anastomosis after resection for squamous cell carcinoma.

Methods: A prospective randomized controlled trial was undertaken in 63 patients with curatively resectable squamous cell cancer of the thoracic esophagus between 1996 and 1999. Patients were randomized to receive either a hand-sewn (32 patients) or circular stapled (31 patients) cervical esophagogastric anastomosis.

Results: The mean operating time was longer when the hand-sewn method was used (524 vs. 447 min, P < 0.001). Anastomotic leakage was noted in seven patients (22%) in the hand-sewn group and eight patients (26%) in the stapler group (P = NS). Hospital mortality occurred in four patients (13%) of the hand-sewn group and in three patients (10%) of the stapler group (P = NS). After the operation, four patients (14%) in the hand-sewn group and five patients (18%) in the stapler group developed a benign esophageal stricture (P = NS). The mean follow-up time was 24 months, and the rates of freedom from benign stricture and survival were comparable in each group.

Conclusions: Performing cervical esophagogastric anastomoses using a circular mechanical stapler had a shorter operating time and a comparable outcome to the hand-sewn method. The circular mechanical stapler could be used as an alternative for cervical esophagogastric anastomosis after resection for esophageal squamous cell cancer.

PubMed Disclaimer