Tracking the concentration of heterotrophic plate count bacteria from the source to the consumer's tap
- PMID: 15145587
- DOI: 10.1016/j.ijfoodmicro.2003.08.021
Tracking the concentration of heterotrophic plate count bacteria from the source to the consumer's tap
Abstract
The goal of this project was to quantify the concentration of heterotrophic plate count (HPC) bacteria within water reaching consumer's taps, and from the sources used by a major utility serving the City of Tucson, AZ. With this information, the amounts and sources of HPC bacteria consumed at the tap could be determined. Samples of water were collected on a monthly basis from two well fields, the CAVSARP recovery well field and Southern Avra Valley well field which serves as one of the groundwater sources for Tucson, AZ, and the distribution system which serves the same homes from which tap water was also tested. The average concentration of HPC in source waters within Southern Avra Valley Wells was 56 CFU/ml (range 1-1995/ml). From the CAVSARP recovery well field, corresponding values were 38 CFU/ml (1 to 502 CFU/ml). Unblended groundwater in the chlorinated distribution system averaged 22 CFU/ml (range 1-794). Blended water at the chlorinated distribution site averaged 47 CFU/ml (range 10-158). There was a major shift in the percentage of gram negative to gram-positive bacteria from the wells to the distribution system, to the tap. In the surface CAP source water, 76% of the bacteria were gram-negative compared to 27% gram-negative in the CAVSARP recovery wells. In contrast, Avra Valley wells contained 17% gram-negative bacteria. In both the Tucson groundwater distribution sites and blended distribution sites, the corresponding number of gram negative bacteria was 12%. Finally at the tap, only 0.2% of the bacteria were gram-negative. The average number of bacteria in household taps averaged 3072 HPC/ml and was equal or greater than 500 ml 68% of the time. This study shows that the number of HPC bacteria increases dramatically from the distribution system to the consumers tap. Thus, the major source of bacteria ingested by the average consumer in Tucson originates from bacteria within the household distribution system or the household tap, rather than from source waters or the distribution system. It is also clear that consumers' regularly consume more than 500 HPC/ml from drinking water taken from the household tap.
Copyright 2003 Elsevier B.V.
Similar articles
-
Contribution of drinking water to the weekly intake of heterotrophic bacteria from diet in the United States.Water Res. 2005 Jan;39(1):257-63. doi: 10.1016/j.watres.2004.09.010. Water Res. 2005. PMID: 15607184
-
Heterotrophic plate count and consumer's health under special consideration of water softeners.Int J Food Microbiol. 2004 May 1;92(3):365-73. doi: 10.1016/j.ijfoodmicro.2003.08.007. Int J Food Microbiol. 2004. PMID: 15145595
-
Influence of pipe materials and VBNC cells on culturable bacteria in a chlorinated drinking water model system.J Microbiol Biotechnol. 2007 Sep;17(9):1558-62. J Microbiol Biotechnol. 2007. PMID: 18062238
-
Heterotrophic plate count bacteria--what is their significance in drinking water?Int J Food Microbiol. 2004 May 1;92(3):265-74. doi: 10.1016/j.ijfoodmicro.2003.08.017. Int J Food Microbiol. 2004. PMID: 15145585 Review.
-
Assessment of the microbial integrity, sensu G.S. Wilson, of piped and bottled drinking water in the condition as ingested.Int J Food Microbiol. 2004 May 1;92(3):375-90. doi: 10.1016/j.ijfoodmicro.2003.08.015. Int J Food Microbiol. 2004. PMID: 15145596 Review.
Cited by
-
Effect of household pipe materials on formation and chlorine resistance of the early-stage biofilm: various interspecific interactions exhibited by the same microbial biofilm in different pipe materials.Arch Microbiol. 2024 Jun 10;206(7):295. doi: 10.1007/s00203-024-04013-4. Arch Microbiol. 2024. PMID: 38856934
-
Present-day monitoring underestimates the risk of exposure to pathogenic bacteria from cold water storage tanks.PLoS One. 2018 Apr 12;13(4):e0195635. doi: 10.1371/journal.pone.0195635. eCollection 2018. PLoS One. 2018. PMID: 29649274 Free PMC article.
-
Biological Stability of Drinking Water: Controlling Factors, Methods, and Challenges.Front Microbiol. 2016 Feb 1;7:45. doi: 10.3389/fmicb.2016.00045. eCollection 2016. Front Microbiol. 2016. PMID: 26870010 Free PMC article. Review.
-
Recovery of microbiological quality of long-term stagnant tap water in university buildings during the COVID-19 pandemic.Sci Total Environ. 2022 Feb 1;806(Pt 2):150616. doi: 10.1016/j.scitotenv.2021.150616. Epub 2021 Sep 27. Sci Total Environ. 2022. PMID: 34592279 Free PMC article.
-
Composition and dynamics of bacterial communities of a drinking water supply system as assessed by RNA- and DNA-based 16S rRNA gene fingerprinting.Appl Environ Microbiol. 2006 Mar;72(3):1858-72. doi: 10.1128/AEM.72.3.1858-1872.2006. Appl Environ Microbiol. 2006. PMID: 16517632 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous