Transthoracic echocardiography using second harmonic imaging with Valsalva manoeuvre for the detection of right to left shunts
- PMID: 15147659
- DOI: 10.1016/S1525-2167(03)00076-3
Transthoracic echocardiography using second harmonic imaging with Valsalva manoeuvre for the detection of right to left shunts
Abstract
Aims: To assess transthoracic echocardiography (TTE) using second harmonic imaging with Valsalva manoeuvre compared to transesophageal echocardiography (TEE) for the diagnosis of right to left cardiac and pulmonary shunts.
Methods and results: One hundred and ten patients referred for TEE underwent TTE with bubble contrast. Bubbles in the left atrium within three cardiac cycles were considered diagnostic for a patent foramen ovale (PFO) and later as a pulmonary shunt. Greater than 20 bubbles in the left atrium was considered a large shunt and less than 20 a small shunt. TEE was performed immediately afterwards and read blinded to the TTE results. Pick-up rates were similar with 19 TEE positive (13 PFO) and 18 TTE positive (14 PFO) patients. There were five TEE positive/TTE negative cases who had significantly poorer TTE image quality score (2.7 +/- 0.8 vs 1.9 +/- 0.6, p < 0.05). There were six TEE negative/TTE positive cases, two cases requiring Valsalva manoeuvre to become positive. The Valsalva manoeuvre significantly increased the number of bubbles shunting (10 +/- 11 vs 20 +/- 19, p < 0.005).
Conclusion: TTE with Valsalva manoeuvre is as good as TEE in diagnosing shunts. Valsalva manoeuvre increases the size of shunt. Both techniques produce false negative results.
Similar articles
-
Second harmonic transthoracic echocardiography: the new reference screening method for the detection of patent foramen ovale.Eur J Echocardiogr. 2004 Dec;5(6):449-52. doi: 10.1016/j.euje.2004.04.004. Eur J Echocardiogr. 2004. PMID: 15556821
-
Transthoracic echocardiography using second harmonic imaging: diagnostic alternative to transesophageal echocardiography for the detection of atrial right to left shunt in patients with cerebral embolic events.J Am Coll Cardiol. 1999 Nov 15;34(6):1823-30. doi: 10.1016/s0735-1097(99)00412-x. J Am Coll Cardiol. 1999. PMID: 10577576
-
Transthoracic second harmonic two- and three-dimensional echocardiography for detection of patent foramen ovale.Eur J Echocardiogr. 2010 Jan;11(1):57-63. doi: 10.1093/ejechocard/jep165. Epub 2009 Nov 12. Eur J Echocardiogr. 2010. PMID: 19910318
-
The use of contrast echocardiography for the detection of cardiac shunts.Eur J Echocardiogr. 2007 Jun;8(3):S2-12. doi: 10.1016/j.euje.2007.03.006. Epub 2007 Apr 25. Eur J Echocardiogr. 2007. PMID: 17462958 Review.
-
Accuracy of conventional transthoracic echocardiography for the diagnosis of intracardiac right-to-left shunt: a meta-analysis of prospective studies.Echocardiography. 2014 Oct;31(9):1036-48. doi: 10.1111/echo.12583. Epub 2014 Apr 2. Echocardiography. 2014. PMID: 24689727
Cited by
-
Hepatopulmonary syndrome: an update.Sao Paulo Med J. 2009 Jul;127(4):223-30. doi: 10.1590/s1516-31802009000400008. Sao Paulo Med J. 2009. PMID: 20011928 Free PMC article. Review.
-
Aortic Root Downward Movement as a Novel Method for Identification of an Adequately Performed Valsalva Maneuver to Detect Patent Foramen Ovale during Transesophageal Echocardiograph.Diagnostics (Basel). 2022 Apr 13;12(4):980. doi: 10.3390/diagnostics12040980. Diagnostics (Basel). 2022. PMID: 35454028 Free PMC article.
-
Patent foramen ovale and stroke.J Cardiol. 2010 Sep;56(2):134-41. doi: 10.1016/j.jjcc.2010.05.008. Epub 2010 Jun 29. J Cardiol. 2010. PMID: 20591626 Free PMC article. Review.
-
Modified Method of Contrast Transthoracic Echocardiography for the Diagnosis of Patent Foramen Ovale.Biomed Res Int. 2019 May 9;2019:9828539. doi: 10.1155/2019/9828539. eCollection 2019. Biomed Res Int. 2019. PMID: 31211145 Free PMC article. Clinical Trial.
-
Venous air embolism during surgery, especially cesarean delivery.J Korean Med Sci. 2008 Oct;23(5):753-61. doi: 10.3346/jkms.2008.23.5.753. J Korean Med Sci. 2008. PMID: 18955777 Free PMC article. Review.