Biocompatibility of beta-stabilizing elements of titanium alloys
- PMID: 15147816
- DOI: 10.1016/j.biomaterials.2004.01.021
Biocompatibility of beta-stabilizing elements of titanium alloys
Abstract
In comparison to the presently used alpha + beta titanium alloys for biomedical applications, beta-titanium alloys have many advantageous mechanical properties, such as an improved wear resistance, a high elasticity and an excellent cold and hot formability. This will promote their future increased application as materials for orthopaedic joint replacements. Not all elements with beta-stabilizing properties in titanium alloys are suitable for biomaterial applications-corrosion and wear processes cause a release of these alloying elements to the surrounding tissue. In this investigation, the biocompability of alloying elements for beta- and near beta-titanium alloys was tested in order to estimate their suitability for biomaterial components. Titanium (grade 2) and the implant steel X2CrNiMo18153 (AISI 316 L) were tested as reference materials. The investigation included the corrosion properties of the elements, proliferation, mitochondrial activity, cell morphology and the size of MC3T3-E1 cells and GM7373 cells after 7 days incubation in direct contact with polished slices of the metals. The statistical significance was considered by Weir-test and Lord-test (alpha = 0.05). The biocompatibility range of the investigated metals is (decreasing biocompatibility): niobium-tantalum, titanium, zirconium-aluminium-316 L-molybdenum.
Similar articles
-
In vitro corrosion and biocompatibility of binary magnesium alloys.Biomaterials. 2009 Feb;30(4):484-98. doi: 10.1016/j.biomaterials.2008.10.021. Epub 2008 Nov 9. Biomaterials. 2009. PMID: 19000636
-
In vitro biocompatibility, mechanical properties, and corrosion resistance of Ti-Zr-Nb-Ta-Pd and Ti-Sn-Nb-Ta-Pd alloys.J Biomed Mater Res. 1995 Jul;29(7):893-9. doi: 10.1002/jbm.820290715. J Biomed Mater Res. 1995. PMID: 7593029
-
[Corrosion behaviour, metal release and biocompatibility of implant materials coated by TiO2-sol gel chemistry].Biomed Tech (Berl). 2005 Oct;50(10):320-9. doi: 10.1515/BMT.2005.045. Biomed Tech (Berl). 2005. PMID: 16300047 German.
-
Recent advances in the design of titanium alloys for orthopedic applications.Expert Rev Med Devices. 2005 Nov;2(6):741-8. doi: 10.1586/17434440.2.6.741. Expert Rev Med Devices. 2005. PMID: 16293101 Review.
-
Mechanical biocompatibilities of titanium alloys for biomedical applications.J Mech Behav Biomed Mater. 2008 Jan;1(1):30-42. doi: 10.1016/j.jmbbm.2007.07.001. Epub 2007 Aug 27. J Mech Behav Biomed Mater. 2008. PMID: 19627769 Review.
Cited by
-
Ti-O-N/Ti composite coating on Ti-6Al-4V: surface characteristics, corrosion properties and cellular responses.J Mater Sci Mater Med. 2015 Mar;26(3):144. doi: 10.1007/s10856-015-5413-7. Epub 2015 Mar 4. J Mater Sci Mater Med. 2015. PMID: 25737126
-
In vitro response of human peripheral blood mononuclear cells to AISI 316L austenitic stainless steel subjected to nitriding and collagen coating treatments.J Mater Sci Mater Med. 2015 Feb;26(2):100. doi: 10.1007/s10856-015-5446-y. Epub 2015 Feb 6. J Mater Sci Mater Med. 2015. PMID: 25655502
-
Microstructure and Defect-Based Fatigue Mechanism Evaluation of Brazed Coaxial Ti/Al2O3 Joints for Enhanced Endoprosthesis Design.Materials (Basel). 2021 Dec 20;14(24):7895. doi: 10.3390/ma14247895. Materials (Basel). 2021. PMID: 34947498 Free PMC article.
-
In vitro study on an antibacterial Ti-5Cu alloy for medical application.J Mater Sci Mater Med. 2016 May;27(5):91. doi: 10.1007/s10856-016-5698-1. Epub 2016 Mar 14. J Mater Sci Mater Med. 2016. PMID: 26975748
-
Influence of Zirconium on the Microstructure, Selected Mechanical Properties, and Corrosion Resistance of Ti20Ta20Nb20(HfMo)20-xZrx High-Entropy Alloys.Materials (Basel). 2024 Jun 4;17(11):2730. doi: 10.3390/ma17112730. Materials (Basel). 2024. PMID: 38893994 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources