Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1992;66(4):291-5.
doi: 10.1007/BF02307176.

Experimental data from closed chamber gas uptake studies in rodents suggest lower uptake rate of chemical than calculated from literature values on alveolar ventilation

Affiliations

Experimental data from closed chamber gas uptake studies in rodents suggest lower uptake rate of chemical than calculated from literature values on alveolar ventilation

G Johanson et al. Arch Toxicol. 1992.

Abstract

Experimental data obtained in vivo with the closed-chamber gas uptake technique have been reported for a series of volatile chemicals. Pharmacokinetic analyses of these data have been performed either by using a two-compartment model or physiological models. In the former the transfer rate of chemical from ambient air to body is defined by the clearance of uptake. In the latter models the transfer rate depends on alveolar ventilation, cardiac output, and blood: air partition coefficient. In this communication we describe the quantitative relationship between clearance of uptake and alveolar ventilation, cardiac output, and blood: air partition coefficient. Theoretical values of clearance of uptake were calculated for a variety of volatile chemicals using literature data on alveolar ventilation, cardiac output, and blood: air partition coefficient. For most chemicals the experimentally determined values in rats and mice were about 60% of the theoretical values. This suggests that the inhalatory uptake rate of chemical may be overestimated if literature values of alveolar ventilation are used in physiological pharmacokinetic models for rodents.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Am Ind Hyg Assoc J. 1979 Mar;40(3):207-29 - PubMed
    1. Toxicol Lett. 1983 Dec;19(3):293-7 - PubMed
    1. Toxicol Appl Pharmacol. 1981 Dec;61(3):451-9 - PubMed
    1. Fundam Appl Toxicol. 1991 Jan;16(1):81-91 - PubMed
    1. Toxicol Lett. 1987 Mar;36(1):9-14 - PubMed

Publication types

LinkOut - more resources