Preload-adjusted right ventricular maximal power: concept and validation
- PMID: 15155255
- DOI: 10.1152/ajpheart.00123.2004
Preload-adjusted right ventricular maximal power: concept and validation
Abstract
Right ventricular (RV) maximal power (PWR(mx)) is dependent on preload. The objective of this study was to test our hypothesis that the PWR(mx) versus end-diastolic volume (EDV) relationship, analogous to the load-independent stroke work (SW) versus EDV relationship (preload-recruitable SW, PRSW), is linear, with the PWR x-axis intercept (V(0PWR)) corresponding to the PRSW intercept (V(0SW)). If our hypothesis is correct, the preload sensitivity of PWR(mx) could be eliminated by adjusting for EDV and V(0PWR). Ten dogs were instrumented with a pulmonary flow probe, micromanometers, and RV conductance catheter. Data were obtained during bicaval occlusions under various conditions and fitted to PWR(mx) = a.(EDV - V(0PWR))(beta), where a is the slope of the relationship. The PWR(mx) versus EDV relationship did not deviate from linearity (beta = 1.09, P = not significant vs. 1), and V(0PWR) correlated with V(0SW) (r = 0.93, P <0.0001). V(0PRW) was related to steady-state EDV and left ventricular end-diastolic pressure, allowing for estimation of V(0PWR) (V(0Est)) and single-beat PWR(mx) preload adjustment. Dividing PWR(mx) by the difference of EDV and V(0PWR) (PAMP(V0PWR)) eliminated preload dependency down to 50% of the baseline EDV. PWR(mx) adjustment using V(0Est) (PAMP(V0Est)) showed similar preload independency. Enhancing contractility increased PAMP(V0PWR) and PAMP(V0Est) from 176 +/- 52 to 394 +/- 205 W/ml x 10(4) and 145 +/- 51 to 404 +/- 261 W/ml x 10(4), respectively, accompanied by an increase of PRSW from 13.0 +/- 4.5 to 29.7 +/- 16.4 mmHg (all P <0.01). PAMP(V0PWR) and PAMP(V0Est) correlated with PRSW (r = 0.85; r = 0.77; both P <0.001). Numerical modeling confirmed the accuracy of our experimental data. Thus preload adjustment of PWR(mx) should consider a linear PWR(mx) versus EDV relationship with distinct V(0PWR). PAMP(V0PWR) is a preload-independent estimate of RV contractility that may eventually be determined noninvasively.
Similar articles
-
The limitations of preload-adjusted maximal power as an index of right ventricular contractility.Anesth Analg. 2002 Oct;95(4):798-804, table of contents. doi: 10.1097/00000539-200210000-00003. Anesth Analg. 2002. PMID: 12351248
-
Right ventricular preload recruitable stroke work, end-systolic pressure-volume, and dP/dtmax-end-diastolic volume relations compared as indexes of right ventricular contractile performance in conscious dogs.Circ Res. 1992 Jun;70(6):1169-79. doi: 10.1161/01.res.70.6.1169. Circ Res. 1992. PMID: 1576738
-
Single-beat determination of preload recruitable stroke work relationship: derivation and evaluation in conscious dogs.J Am Coll Cardiol. 2000 Feb;35(2):502-13. doi: 10.1016/s0735-1097(99)00566-5. J Am Coll Cardiol. 2000. PMID: 10676701
-
Preload-adjusted maximal power of right ventricle: contribution of end-systolic P-V relation intercept.Am J Physiol Heart Circ Physiol. 2002 Oct;283(4):H1681-7. doi: 10.1152/ajpheart.00340.2002. Epub 2002 Jun 13. Am J Physiol Heart Circ Physiol. 2002. PMID: 12234823
-
Ketamine depresses myocardial contractility as evaluated by the preload recruitable stroke work relationship in chronically instrumented dogs with autonomic nervous system blockade.Anesthesiology. 1992 Apr;76(4):564-72. doi: 10.1097/00000542-199204000-00013. Anesthesiology. 1992. PMID: 1550282 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical