Ultrapure dialysate decreases plasma pentosidine, a marker of "carbonyl stress"
- PMID: 15168382
- DOI: 10.1053/j.ajkd.2004.02.015
Ultrapure dialysate decreases plasma pentosidine, a marker of "carbonyl stress"
Abstract
Background: Advanced glycation end products (AGEs) and their reactive carbonyl precursors accumulate in renal failure ("carbonyl stress"). Carbonyl stress derives from a broad derangement in the nonenzymatic biochemistry of both carbohydrates and lipids. We tested the influence of dialysate quality on plasma level of pentosidine, an AGE moiety taken as a surrogate marker of carbonyl stress, in hemodialysis patients.
Methods: Plasma pentosidine is measured by means of high-performance liquid chromatography in patients hemodialyzed successively with a conventional and an ultrapure endotoxin-free dialysate.
Results: Dialysate endotoxin level decreased from 0.040 +/- 0.017 EU/mL before the switch to the new water supply system to less than the detection limit (<0.001 EU/mL) after the switch. Plasma pentosidine levels decreased from 1.55 +/- 0.61 nmol/mL before the switch to 1.38 +/- 0.52 nmol/mL (P < 0.0001) and 1.31 +/- 0.50 nmol/mL (P < 0.0001) 3 and 6 months after the switch to an ultrapure dialysate, respectively. Decreases in plasma pentosidine levels were similar regardless of dialyzer membrane type; ie, high-flux polysulfone, high-flux polymethylmethacrylate, and low-flux cellulose acetate membranes. Unexpectedly, plasma triglyceride levels decreased from 150 +/- 116 mg/dL (1.69 +/- 1.31 mmol/L) before the switch to 124 +/- 79 mg/dL (1.40 +/- 0.89 mmol/L; P < 0.01) and 119 +/- 75 mg/dL (1.34 +/- 0.85 mmol/L; P < 0.01) 3 and 6 months after the switch despite unchanged total cholesterol levels, respectively. Changes in pentosidine levels were unrelated to those in triglycerides, and both were unrelated to C-reactive protein levels, which remained stable throughout the study.
Conclusion: Ultrapure dialysate reduces plasma pentosidine levels and improves plasma triglyceride levels in hemodialysis patients through still undefined mechanisms.
Similar articles
-
Ultrapure dialysate reduces plasma levels of beta2-microglobulin and pentosidine in hemodialysis patients.Blood Purif. 2005;23(4):311-6. doi: 10.1159/000086554. Epub 2005 Jun 23. Blood Purif. 2005. PMID: 15980621
-
Influence of hemodialysis membrane type on pentosidine plasma level, a marker of "carbonyl stress".Kidney Int. 1999 Jun;55(6):2487-92. doi: 10.1046/j.1523-1755.1999.00468.x. Kidney Int. 1999. PMID: 10354298
-
The effect of dialysis membrane type on plasma concentrations of pentosidine, a marker of carbonyl stress, in hemodialyzed patients.Pol Arch Med Wewn. 2009 Oct;119(10):614-20. Pol Arch Med Wewn. 2009. PMID: 19847136
-
AGEs and carbonyl stress: potential pathogenetic factors of long-term uraemic complications.Nephrol Dial Transplant. 2000;15 Suppl 2:7-11. doi: 10.1093/ndt/15.suppl_1.7. Nephrol Dial Transplant. 2000. PMID: 11051031 Review.
-
Hemodialysis techniques and advanced glycation end products.Contrib Nephrol. 2001;(131):33-9. doi: 10.1159/000060058. Contrib Nephrol. 2001. PMID: 11125561 Review. No abstract available.
Cited by
-
Hemodialysis and water quality.Semin Dial. 2013 Jul-Aug;26(4):427-38. doi: 10.1111/sdi.12113. Semin Dial. 2013. PMID: 23859187 Free PMC article. Review.
-
Is correction for protein concentration appropriate for protein adduct dosimetry? Hypothesis and clues from an aflatoxin B1-exposed population.Cancer Sci. 2007 Feb;98(2):140-6. doi: 10.1111/j.1349-7006.2006.00380.x. Cancer Sci. 2007. PMID: 17233831 Free PMC article.
-
Impact of improving quality of dialysis fluid on oxidative stress and lipid profile in hemodialysis patients.ISRN Nephrol. 2012 Dec 19;2013:717849. doi: 10.5402/2013/717849. eCollection 2013. ISRN Nephrol. 2012. PMID: 24967229 Free PMC article.
-
Water quality in conventional and home haemodialysis.Nat Rev Nephrol. 2012 Dec;8(12):725-34. doi: 10.1038/nrneph.2012.241. Epub 2012 Oct 23. Nat Rev Nephrol. 2012. PMID: 23090444 Review.
-
Endotoxin-Retentive Filters for the Online Preparation of Ultrapure Dialysis Fluid and Non-Pyrogenic Substitution Fluid: A Critical Review and Reference Guide.Membranes (Basel). 2025 Feb 5;15(2):51. doi: 10.3390/membranes15020051. Membranes (Basel). 2025. PMID: 39997677 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials