Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004 Apr;28(1):9-21.
doi: 10.3109/03093640409167920.

From major amputation to prosthetic outcome: a prospective study of 190 patients in a defined population

Affiliations

From major amputation to prosthetic outcome: a prospective study of 190 patients in a defined population

A Johannesson et al. Prosthet Orthot Int. 2004 Apr.

Abstract

In this prospective study, the overall treatment and outcome of patients that underwent major lower limb amputation in a defined population is described. The study was performed over a five year period in the Health Care District of North-East Skåne, Sweden. Some 190 patients, permanent inhabitants of the Health Care District, underwent major lower limb amputation. Sixteen (16) of these patients had amputations before the study started and went through late second leg amputation during the period. One hundred and seventy four (174) patients had primary major amputation. Seventy nine (79) were men and 95 were women, with a median age of 81. The re-amputation rate was 17% although the primary knee preservation ratio was as high as 3.0:1. Rigid dressing was the standard method following trans-tibial amputation and was used for 5-7 days. ICEROSS silicone liner was used for compression therapy in 90% of all cases that resulted in delivery of a prosthesis. Prostheses were delivered to 43% of all patients with primary amputations. These patients spent a median of 13 days at the orthopaedic clinic. 55 days at the rehabilitation unit. Pressure casting was used as a standard method in the production of the prosthetic socket. ICEX carbon-fibre socket was used in 52%. New procedures, treatments and techniques were introduced, standardised and evaluated whilst the routines in the hospital were reorganised. In this way, a system has been implemented that better guarantees the outcome of the whole procedure and the service received by this category of patients.

PubMed Disclaimer

Comment in

Publication types

Substances

LinkOut - more resources