Clinical and physical quality assurance for intensity modulated radiotherapy of prostate cancer
- PMID: 15172148
- DOI: 10.1016/j.radonc.2004.02.016
Clinical and physical quality assurance for intensity modulated radiotherapy of prostate cancer
Abstract
The implementation of intensity modulated radiotherapy (IMRT) for patients with prostate cancer in daily routine has been elaborated at our department. Our quality assurance (QA) concept is one method to pave the way for initiating IMRT treatments for starting institutions. A clinical quality assurance (CQA) procedure has been set-up for all patients before and throughout the course of radiotherapy. Simultaneously medical physicists established a physical quality assurance (PQA) concept that has been followed for all patients as well. Alternative CQA and PQA procedures are discussed. The literature is reviewed and discussed with special respect to quality assurance in IMRT of prostate cancer patients.
Similar articles
-
[Preliminary results of the assessment of intensity modulated radiotherapy (IMRT) for prostatic and head and neck tumors (STIC 2001)].Cancer Radiother. 2004 Nov;8 Suppl 1:S121-7. Cancer Radiother. 2004. PMID: 15679257 French.
-
Process control analysis of IMRT QA: implications for clinical trials.Phys Med Biol. 2008 Sep 21;53(18):5193-205. doi: 10.1088/0031-9155/53/18/023. Epub 2008 Aug 26. Phys Med Biol. 2008. PMID: 18728311
-
Health-related quality of life in patients with locally advanced prostate cancer after 76 Gy intensity-modulated radiotherapy vs. 70 Gy conformal radiotherapy in a prospective and longitudinal study.Int J Radiat Oncol Biol Phys. 2007 Nov 1;69(3):656-61. doi: 10.1016/j.ijrobp.2007.04.013. Epub 2007 May 23. Int J Radiat Oncol Biol Phys. 2007. PMID: 17512127
-
Quality assurance of intensity-modulated radiotherapy.Semin Radiat Oncol. 2002 Jul;12(3):219-28. doi: 10.1053/srao.2002.33700. Semin Radiat Oncol. 2002. PMID: 12118387 Review.
-
Practical aspects of inverse-planned intensity-modulated radiation therapy for prostate cancer: a radiation treatment planner's perspective.Can J Urol. 2005 Jun;12 Suppl 2:48-52. Can J Urol. 2005. PMID: 16018834 Review.
Cited by
-
SWIMRT: a graphical user interface using sliding window algorithm to construct a fluence map machine file.J Appl Clin Med Phys. 2006 May 25;7(2):69-85. doi: 10.1120/jacmp.v7i2.2231. J Appl Clin Med Phys. 2006. PMID: 17533330 Free PMC article.
-
Evaluation of dosimetric effect of leaf position in a radiation field of an 80 leaf multileaf collimator fitted to the LINAC head as tertiary collimator.J Appl Clin Med Phys. 2006 Aug 24;7(3):43-54. doi: 10.1120/jacmp.v7i3.2310. J Appl Clin Med Phys. 2006. PMID: 17533348 Free PMC article.
-
Practical guidelines for routine intensity-modulated radiotherapy verification: pre-treatment verification with portal dosimetry and treatment verification with in vivo dosimetry.Br J Radiol. 2010 Nov;83(995):949-57. doi: 10.1259/bjr/31573847. Br J Radiol. 2010. PMID: 20965905 Free PMC article.
-
Clinical Evaluation of a Two-dimensional Liquid-Filled Ion chamber Detector Array for Verification of High Modulation Small Fields in Radiotherapy.J Med Phys. 2019 Apr-Jun;44(2):91-98. doi: 10.4103/jmp.JMP_4_19. J Med Phys. 2019. PMID: 31359926 Free PMC article.
-
Statistical analysis of IMRT dosimetry quality assurance measurements for local delivery guideline.Radiat Oncol. 2011 Mar 28;6:27. doi: 10.1186/1748-717X-6-27. Radiat Oncol. 2011. PMID: 21439096 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical