Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1992 Sep;25(9):1027-45.
doi: 10.1016/0021-9290(92)90038-3.

A transversely isotropic biphasic finite element model of the meniscus

Affiliations
Comparative Study

A transversely isotropic biphasic finite element model of the meniscus

R L Spilker et al. J Biomech. 1992 Sep.

Abstract

A finite element model of the meniscus is presented, based on an axisymmetric geometric approximation of the menisci and a biphasic description of the tissue as a mixture of solid and fluid components. The highly fibrous nature of the meniscal tissue is accounted for by using a fiber-reinforced, transversely isotropic description of the solid phase. This model is used to study the response of a meniscus resting on a perfectly lubricated tibial surface and subjected to distributed loads applied to the femoral surface, and to examine the effects of changes in loading conditions at the femoral and tibial interfaces. Quantities of interest include the stress, pressure and strain distributions at discrete times early in the meniscal response, and the flow of the fluid phase relative to the solid phase. Of particular interest are regions of large tensile strains which could lead to meniscal failures such as the bucket-handle tear. We show that all components of strain are positive in regions of the outer third of the meniscus, and that the maximum tensile strain perpendicular to the circumferentially arranged fibers (largest principal strain in the axisymmetric cross section) is positive throughout most of the cross section. Changing the partition of the load on the femoral surface and the permeability at the tibial surface changes the time-dependent response, but has little effect on the strain distributions at times of the order of 5 s considered in this study. The inclusion of a transversely isotropic, fibrous representation of the solid phases is shown to be essential to proper meniscal simulation. The results demonstrate the importance of the biphasic representation since the fluid phase is shown to carry a significant part of the applied load.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources