Abstract
A technique for performing allograft-augmented revision total knee replacement (TKR) using computer assistance is described, on the basis of the results in 14 patients. Bone deficits were made up with impaction grafting. Femoral grafting was made possible by the construction of a retaining wall or dam which allowed pressurisation and retention of the graft. Tibial grafting used a mixture of corticocancellous and morsellised allograft. The position of the implants was monitored by the computer system and adjusted while the cement was setting. The outcome was determined using a six-parameter, quantitative technique (the Perth CT protocol) which measured the alignment of the prosthesis and provided an objective score. The final outcomes were not perfect with errors being made in femoral rotation and in producing a mismatch between the femoral and tibial components. In spite of the shortcomings the alignments were comparable in accuracy with those after primary TKR. Computer assistance shows considerable promise in producing accurate alignment in revision TKR with bone deficits.
Comment in
-
Computer-assisted total knee replacement.J Bone Joint Surg Br. 2005 Aug;87(8):1164. doi: 10.1302/0301-620X.87B8.16557. J Bone Joint Surg Br. 2005. PMID: 16049259 No abstract available.
Similar articles
-
Computer-assisted total knee arthroplasty: Does the tibial component remain at malposition risk?Orthop Traumatol Surg Res. 2010 Sep;96(5):536-42. doi: 10.1016/j.otsr.2009.11.017. Epub 2010 Jun 4. Orthop Traumatol Surg Res. 2010. PMID: 20605549
-
[Bone morphing system for rotational alignment in total knee arthroplasty].Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2008 Jan;22(1):12-5. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2008. PMID: 18361228 Chinese.
-
Navigation knee replacement.Int Orthop. 2009 Feb;33(1):7-10. doi: 10.1007/s00264-008-0671-3. Epub 2008 Oct 29. Int Orthop. 2009. PMID: 18958468 Free PMC article. Review.
-
Morselized bone grafting in revision arthroplasty of the knee: a retrospective analysis of 34 reconstructions after 2-9 years.Acta Orthop. 2008 Oct;79(5):683-8. doi: 10.1080/17453670810016713. Acta Orthop. 2008. PMID: 18839376
-
Applying computer-assisted navigation techniques to total hip and knee arthroplasty.Am J Orthop (Belle Mead NJ). 2011 Aug;40(8):419-26. Am J Orthop (Belle Mead NJ). 2011. PMID: 22016871 Review.
Cited by
-
Sagittal femoral bowing contributes to distal femoral valgus angle deviation in malrotated preoperative radiographs.BMC Musculoskelet Disord. 2022 Jun 15;23(1):579. doi: 10.1186/s12891-022-05542-z. BMC Musculoskelet Disord. 2022. PMID: 35705952 Free PMC article.
-
Computer-assisted revision of total knee arthroplasty.Knee Surg Sports Traumatol Arthrosc. 2009 Oct;17(10):1166-71. doi: 10.1007/s00167-009-0769-1. Epub 2009 Mar 21. Knee Surg Sports Traumatol Arthrosc. 2009. PMID: 19305973
-
The use of navigation to achieve planned coronal alignment during cemented revision total knee arthroplasty: a technical note and case series.Eur J Orthop Surg Traumatol. 2025 Aug 11;35(1):345. doi: 10.1007/s00590-025-04471-6. Eur J Orthop Surg Traumatol. 2025. PMID: 40788402
-
Navigation in total knee arthroplasty. A multicenter study.Int Orthop. 2006 Dec;30(6):536-40. doi: 10.1007/s00264-006-0126-7. Epub 2006 May 31. Int Orthop. 2006. PMID: 16736149 Free PMC article. Clinical Trial.
-
The influence of computer-assisted surgery on rotational, coronal and sagittal alignment in revision total knee arthroplasty.BMC Musculoskelet Disord. 2014 Mar 19;15:94. doi: 10.1186/1471-2474-15-94. BMC Musculoskelet Disord. 2014. PMID: 24646028 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical