Multicenter Study
. 2004 May;93(5):583-8.
doi: 10.1111/j.1651-2227.2004.tb02981.x.

Positive pressure ventilation at neonatal resuscitation: review of equipment and international survey of practice

Affiliations
Multicenter Study

Positive pressure ventilation at neonatal resuscitation: review of equipment and international survey of practice

C P F O'Donnell et al. Acta Paediatr. 2004 May.

Abstract

Background: The equipment used to provide positive pressure ventilation to newborns needing resuscitation at delivery varies between institutions. Devices were reviewed and their use surveyed in a sample of neonatal centres worldwide.

Aim: To determine which equipment is used to resuscitate newborns at delivery in a sample of teaching hospitals around the world.

Methods: A questionnaire was sent via e-mail to a neonatologist at each of 46 NICUs in 23 countries on five continents, asking which resuscitation equipment they used. If it was not returned, follow-up was by e-mail.

Results: Data were obtained from 40 (87%) centres representing 19 countries. Round face masks are used at 34 (85%) centres, anatomically shaped masks are used exclusively at six (15%) and a mixture of types are used at 11 (28%). Straight endotracheal tubes are used exclusively at 36 (90%) centres: shouldered tubes are used infrequently at three of the four centres that have them. The self-inflating bag is the most commonly used manual ventilation device (used at 33 (83%) centres), the Laerdal Infant Resuscitator the most popular model. Flow-inflating bags are used at 10 (25%) centres. The Neopuff Infant Resuscitator is used at 12 (30%) centres. Varying oxygen concentrations are provided during neonatal resuscitation at half of the centres, while 100% oxygen is routinely used at the other half.

Conclusions: This survey shows considerable variation in practice, reflecting this lack of evidence and consequent uncertainty among clinicians. Comparison of the two most popular manual ventilation devices, the Laerdal Infant Resuscitator and the Neopuff Infant Resuscitator, is urgently required.