Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004 Jun;111(6):1183-90.
doi: 10.1016/j.ophtha.2003.09.039.

Computer-assisted measurement of retinal vessel diameters in the Beaver Dam Eye Study: methodology, correlation between eyes, and effect of refractive errors

Affiliations

Computer-assisted measurement of retinal vessel diameters in the Beaver Dam Eye Study: methodology, correlation between eyes, and effect of refractive errors

Tien Yin Wong et al. Ophthalmology. 2004 Jun.

Abstract

Objective: Narrowed retinal arterioles may independently predict cardiovascular disease. We describe a computer-assisted method to measure retinal vessel diameters from digitized fundus photographs in a large population, and examine the correlation of retinal vessel diameters between eyes and whether refractive errors affect these measurements.

Design and population: Population-based, cross-sectional study in Beaver Dam, Wisconsin (n = 4926; age, 43-84 years).

Methods: Retinal photographs were digitized, and all arterioles and venules located in an area 0.5 to 1 disc diameter from the optic disc were measured with the aid of computer software.

Main outcome measures: Summary of retinal arteriolar and venular diameters, and the ratio of their diameters (arteriole:venule ratio [AVR]).

Results: Correlation between right and left eyes was substantial for retinal arteriolar diameters (Pearson correlation coefficient, rho = 0.71) and venular diameters (rho = 0.74), and moderate for the AVR (rho = 0.49). The inverse association of higher blood pressure and smaller retinal arteriolar diameters was similar using data from either one eye or two eyes; arteriolar diameters decreased by 4.1 microm (right eyes), 4.0 microm (left eyes), and 4.0 microm (mean of both eyes) with each 10-mmHg increase in mean arterial blood pressure. A myopic refraction was associated with smaller retinal vessel diameters; arteriolar diameters decreased by 2.8 microm and venular diameters by 3.3 microm with each -1.0-diopter shift towards myopia. However, the pattern and strength of the association of blood pressure and retinal vessel diameters were not altered by variations in refractive errors.

Conclusions: There is good correlation of retinal vessel diameters between eyes. A myopic refraction is associated with smaller retinal vessel diameters. The association of retinal arteriolar diameters and blood pressure seems similar using data from either one eye or two eyes, and is minimally affected by refraction. These data suggest that measurement of retinal vessel diameters from one eye without regard to its refractive status may provide adequate information indicative of a person's retinal vessel caliber if information from two eyes and refraction is unavailable.

PubMed Disclaimer

Publication types

LinkOut - more resources