Which navigation when?
- PMID: 15183701
- DOI: 10.1016/j.injury.2004.05.008
Which navigation when?
Abstract
If a surgeon is considering purchasing a navigation system, several factors have to be evaluated including, the planned applications, the equipment already installed, and the specific knowledge of the surgeon. For use in traumatology, fluoroscopy and more specifically 3-D fluoro-based computer guidance is preferable. These technologies are based on intraoperative acquired arbitrary images in contrast to CT-based techniques, which refer to preoperative acquired images that represent a so called "cannel reality". However, image quality has to be considered as fluoro-picture quality depending on the anatomical area (eg long bones, spine, pelvis) and body mass index. CT-based navigation provides better image quality and accuracy but is not able to visualize reduction processes. Therefore personal experience in courses or by on-site teaching is recommended prior taking the decision.
Similar articles
-
Limitations and pitfalls of 3-D fluoroscopic navigation in orthopaedic trauma surgery.Technol Health Care. 2009;17(2):133-40. doi: 10.3233/THC-2009-0541. Technol Health Care. 2009. PMID: 19564678 No abstract available.
-
Basic principles of CAOS.Injury. 2004 Jun;35 Suppl 1:S-A6-16. doi: 10.1016/j.injury.2004.05.005. Injury. 2004. PMID: 15183698 Review.
-
Accuracy evaluation of direct navigation with an isocentric 3D rotational X-ray system.Med Image Anal. 2006 Apr;10(2):113-24. doi: 10.1016/j.media.2005.04.012. Epub 2005 Aug 11. Med Image Anal. 2006. PMID: 16099196
-
Image guidance in pelvic and acetabular surgery--expectations, success and limitations.Injury. 2007 Apr;38(4):450-62. doi: 10.1016/j.injury.2007.01.024. Epub 2007 Apr 2. Injury. 2007. PMID: 17403522 Review.
-
Image-guided spinal surgery.Int J Med Robot. 2006 Mar;2(1):7-15. doi: 10.1002/rcs.69. Int J Med Robot. 2006. PMID: 17520608 Review.
Cited by
-
Navigation of vertebro-pelvic fixations based on CT-fluoro matching.Eur Spine J. 2010 Nov;19(11):1921-7. doi: 10.1007/s00586-010-1446-2. Epub 2010 Jun 16. Eur Spine J. 2010. PMID: 20556440 Free PMC article.
-
Image guidance can support scaphoid K-wire insertion: an experimental study and initial clinical experience.Int J Comput Assist Radiol Surg. 2013 May;8(3):471-80. doi: 10.1007/s11548-012-0799-x. Epub 2012 Nov 30. Int J Comput Assist Radiol Surg. 2013. PMID: 23196791 Clinical Trial.
-
[Drilling with 3D fluoroscopic navigation in osteonecrosis of the femoral condyle].Unfallchirurg. 2008 May;111(5):344-9. doi: 10.1007/s00113-007-1353-0. Unfallchirurg. 2008. PMID: 18026921 German.
-
Computer-Assisted Orthopedic and Trauma Surgery.Dtsch Arztebl Int. 2020 Nov 20;117(47):793-800. doi: 10.3238/arztebl.2020.0793. Dtsch Arztebl Int. 2020. PMID: 33549155 Free PMC article. Clinical Trial.
-
Computer-aided surgery does not increase the accuracy of dorsal pedicle screw placement in the thoracic and lumbar spine: a retrospective analysis of 2,003 pedicle screws in a level I trauma center.Global Spine J. 2015 Apr;5(2):93-101. doi: 10.1055/s-0034-1396430. Epub 2014 Dec 12. Global Spine J. 2015. PMID: 25844281 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources