Comparison of versions 1.0 AND 1.5 of the UltraSensitive AMPLICOR HIV-1 MONITOR test for subjects with low viral load
- PMID: 15184467
- PMCID: PMC427852
- DOI: 10.1128/JCM.42.6.2774-2776.2004
Comparison of versions 1.0 AND 1.5 of the UltraSensitive AMPLICOR HIV-1 MONITOR test for subjects with low viral load
Abstract
We compared the performance of two UltraSensitive AMPLICOR HIV-1 MONITOR kits (version 1.5 [v1.5] versus v1.0) by retesting 404 plasma samples with low viral loads (<3,000 copies/ml) with both kits. With 292 samples that initially had <50 copies/ml by the v1.0 kit, the v1.5 assay was more sensitive than the v1.0 assay for samples with human immunodeficiency virus type 1 RNA near the 50-copy/ml cutoff (P = 0.0146). Median numbers of copies per milliliter were similar for 112 samples with 50 to 3,000 copies/ml with no difference in sensitivity with a 200-copy/ml cutoff.
Similar articles
-
Comparison of the Generic HIV Viral Load assay with the Amplicor HIV-1 monitor v1.5 and Nuclisens HIV-1 EasyQ v1.2 techniques for plasma HIV-1 RNA quantitation of non-B subtypes: the Kesho Bora preparatory study.J Virol Methods. 2010 Feb;163(2):253-7. doi: 10.1016/j.jviromet.2009.10.005. Epub 2009 Oct 27. J Virol Methods. 2010. PMID: 19837114
-
Comparison of three current viral load assays for the quantitation of human immunodeficiency virus type 1 RNA in plasma.J Virol Methods. 2004 Oct;121(1):93-9. doi: 10.1016/j.jviromet.2004.06.007. J Virol Methods. 2004. PMID: 15350738
-
Evaluation of performance across the dynamic range of the Abbott RealTime HIV-1 assay as compared to VERSANT HIV-1 RNA 3.0 and AMPLICOR HIV-1 MONITOR v1.5 using serial dilutions of 39 group M and O viruses.J Virol Methods. 2007 Apr;141(1):49-57. doi: 10.1016/j.jviromet.2006.11.026. Epub 2006 Dec 20. J Virol Methods. 2007. PMID: 17184853
-
A modified ultrasensitive assay to detect quantified HIV-1 RNA of fewer than 50 copies per milliliter.Am J Clin Pathol. 2003 Aug;120(2):268-70. doi: 10.1309/TRRQ-FWM9-LE9H-427M. Am J Clin Pathol. 2003. PMID: 12931558
-
The significance of HIV viral load assay precision: a review of the package insert specifications of two commercial kits.J Int Assoc Physicians AIDS Care (Chic). 2002 Oct-Dec;1(4):134-40. doi: 10.1177/154510970200100405. J Int Assoc Physicians AIDS Care (Chic). 2002. PMID: 12942672 Review.
Cited by
-
Comparison of the sensitivities of the version 1.5 and version 1.0 ultrasensitive Roche AMPLICOR HIV-1 MONITOR kits at low concentrations of human immunodeficiency virus RNA.J Clin Microbiol. 2004 Jun;42(6):2819-20. doi: 10.1128/JCM.42.6.2819-2820.2004. J Clin Microbiol. 2004. PMID: 15184481 Free PMC article.
-
Cerebrospinal and peripheral human immunodeficiency virus type 1 load in a multisite, randomized, double-blind, placebo-controlled trial of D-Ala1-peptide T-amide for HIV-1-associated cognitive-motor impairment.J Neurovirol. 2006 Jun;12(3):178-89. doi: 10.1080/13550280600827344. J Neurovirol. 2006. PMID: 16877299 Clinical Trial.
-
Influence of episodes of intermittent viremia ("blips") on immune responses and viral load rebound in successfully treated HIV-infected patients.AIDS Res Hum Retroviruses. 2013 Jan;29(1):68-76. doi: 10.1089/AID.2012.0145. Epub 2012 Dec 16. AIDS Res Hum Retroviruses. 2013. PMID: 23121249 Free PMC article. Clinical Trial.
-
Transient detectable viremia and the risk of viral rebound in patients from the Swiss HIV Cohort Study.BMC Infect Dis. 2015 Sep 21;15:382. doi: 10.1186/s12879-015-1120-8. BMC Infect Dis. 2015. PMID: 26392270 Free PMC article.
-
Discordance between viral loads determined by Roche COBAS AMPLICOR human immunodeficiency virus type 1 monitor (version 1.5) Standard and ultrasensitive assays caused by freezing patient plasma in centrifuged becton-dickinson vacutainer brand plasma preparation tubes.J Clin Microbiol. 2005 Sep;43(9):4635-9. doi: 10.1128/JCM.43.9.4635-4639.2005. J Clin Microbiol. 2005. PMID: 16145119 Free PMC article.
References
-
- Brambilla, D., S. Leung, J. Lew, J. Todd, S. Herman, M. Cronin, D. E. Shapiro, J. Bremer, C. Hanson, G. V. Hillyer, G. D. McSherry, R. S. Sperling, R. W. Coombs, and P. S. Reichelderfer. 1998. Absolute copy number and relative change in determinations of human immunodeficiency virus type 1 RNA in plasma: effect of an external standard on kit comparisons. J. Clin. Microbiol. 36:311-314. - PMC - PubMed
-
- Brambilla D., P. S. Reichelderfer, J. W. Bremer, D. E. Shapiro, R. C. Hershow, D. A. Katzenstein, S. M. Hammer, B. Jackson, A. C. Collier, R. S. Sperling, M. G. Fowler, and R. W. Coombs for participating Adult and Pediatric AIDS Clinical Trials Groups, The Women Infant Transmission Study Clinics, and laboratories participating in the Virology Quality Assurance Program. 1999. The contribution of assay variation and biological variation to the total variability of plasma HIV-1 RNA measurement. AIDS 13:2269-2279. - PubMed
-
- Havlir, D., R. Bassett, D. Levitan, P. Gilbert, P. Tebas, A. C. Collier, M. S. Hirsch, C. Ignacio, J. Condra, H. F. Gunthard, D. D. Richman, and J. K. Wong. 2001. Prevalence and predictive value of intermittent viremia with combination HIV therapy. JAMA 286:171-179. - PubMed
-
- Piwowar-Manning, E., T. A. Henderson, L. Brisbin, and J. B. Jackson. 2003. A modified ultrasensitive assay to detect quantified HIV-1 RNA of fewer than 50 copies per milliliter. Am. J. Clin. Pathol. 120:268-270. - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources