Comparison of the sensitivities of the version 1.5 and version 1.0 ultrasensitive Roche AMPLICOR HIV-1 MONITOR kits at low concentrations of human immunodeficiency virus RNA
- PMID: 15184481
- PMCID: PMC427863
- DOI: 10.1128/JCM.42.6.2819-2820.2004
Comparison of the sensitivities of the version 1.5 and version 1.0 ultrasensitive Roche AMPLICOR HIV-1 MONITOR kits at low concentrations of human immunodeficiency virus RNA
Abstract
The sensitivities of the version 1.5 and 1.0 Roche UltraSensitive AMPLICOR HIV-1 MONITOR tests were compared using panels of coded samples of subtype B human immunodeficiency virus type 1 spiked into plasma at predetermined concentrations. Results indicate that the version 1.5 kit is more sensitive than the version 1.0 kit.
Similar articles
-
Comparison of versions 1.0 AND 1.5 of the UltraSensitive AMPLICOR HIV-1 MONITOR test for subjects with low viral load.J Clin Microbiol. 2004 Jun;42(6):2774-6. doi: 10.1128/JCM.42.6.2774-2776.2004. J Clin Microbiol. 2004. PMID: 15184467 Free PMC article.
-
Quantitative and cost comparison of ultrasensitive human immunodeficiency virus type 1 RNA viral load assays: Bayer bDNA quantiplex versions 3.0 and 2.0 and Roche PCR Amplicor monitor version 1.5.J Clin Microbiol. 2000 Mar;38(3):1113-20. doi: 10.1128/JCM.38.3.1113-1120.2000. J Clin Microbiol. 2000. PMID: 10699005 Free PMC article.
-
Multicenter comparison of Roche COBAS AMPLICOR MONITOR version 1.5, Organon Teknika NucliSens QT with Extractor, and Bayer Quantiplex version 3.0 for quantification of human immunodeficiency virus type 1 RNA in plasma.J Clin Microbiol. 2000 Nov;38(11):4034-41. doi: 10.1128/JCM.38.11.4034-4041.2000. J Clin Microbiol. 2000. PMID: 11060065 Free PMC article.
-
Stability of human immunodeficiency virus type 1 RNA in cerebrospinal fluid determined with the AMPLICOR HIV-1 MONITOR test, version 1.5 (ultrasensitive).J Clin Microbiol. 2002 Oct;40(10):3863-4. doi: 10.1128/JCM.40.10.3863-3864.2002. J Clin Microbiol. 2002. PMID: 12354902 Free PMC article.
-
Entirely automated quantification of human immunodeficiency virus type 1 (HIV-1) RNA in plasma by using the ultrasensitive COBAS AMPLICOR HIV-1 monitor test and RNA purification on the MagNA pure LC instrument.J Clin Microbiol. 2003 Mar;41(3):1248-51. doi: 10.1128/JCM.41.3.1248-1251.2003. J Clin Microbiol. 2003. PMID: 12624059 Free PMC article.
Cited by
-
Cerebrospinal and peripheral human immunodeficiency virus type 1 load in a multisite, randomized, double-blind, placebo-controlled trial of D-Ala1-peptide T-amide for HIV-1-associated cognitive-motor impairment.J Neurovirol. 2006 Jun;12(3):178-89. doi: 10.1080/13550280600827344. J Neurovirol. 2006. PMID: 16877299 Clinical Trial.
-
A high-efficiency superhydrophobic plasma separator.Lab Chip. 2016 Feb 7;16(3):553-60. doi: 10.1039/c5lc01235j. Lab Chip. 2016. PMID: 26732765 Free PMC article.
-
Discordance between viral loads determined by Roche COBAS AMPLICOR human immunodeficiency virus type 1 monitor (version 1.5) Standard and ultrasensitive assays caused by freezing patient plasma in centrifuged becton-dickinson vacutainer brand plasma preparation tubes.J Clin Microbiol. 2005 Sep;43(9):4635-9. doi: 10.1128/JCM.43.9.4635-4639.2005. J Clin Microbiol. 2005. PMID: 16145119 Free PMC article.
-
Introduction to a Special Issue of the Journal of Immunological Methods: Building global resource programs to support HIV/AIDS clinical trial studies.J Immunol Methods. 2014 Jul;409:1-5. doi: 10.1016/j.jim.2014.05.016. Epub 2014 Jun 6. J Immunol Methods. 2014. PMID: 24910413 Free PMC article.
References
-
- Holguin, A., B. Aracil, A. Alvarez, C. Barros, and V. Soriano. 2001. Prevalence of human immunodeficiency virus type 1 (HIV-1) non-B subtypes in foreigners living in Madrid, Spain, and comparison of the performances of the AMPLICOR HIV-1 MONITOR version 1.0 and the new automated version 1.5. J. Clin. Microbiol. 39:1850-1854. - PMC - PubMed
-
- Michael, N. L., S. A. Herman, S. Kwok, K. Dreyer, J. Wang, C. Christopherson, J. P. Spadoro, K. K. Young, V. Polonis, F. E. McCutchan, J. Carr, J. R. Mascola, L. L. Jagodzinski, and M. L. Robb. 1999. Development of calibrated viral load standards for group M subtypes of human immunodeficiency virus type 1 and performance of an improved AMPLICOR HIV-1 MONITOR test with isolates of diverse subtypes. J. Clin. Microbiol. 37:2557-2563. - PMC - PubMed
-
- Triques, K., J. Coste, J. L. Perret, C. Segarra, E. Mpoudi, J. Reynes, E. Delaporte, A. Butcher, K. Dreyer, S. Herman, J. Spadoro, and M. Peeters. 1999. Efficiencies of four versions of the AMPLICOR HIV-1 MONITOR test for quantification of different subtypes of human immunodeficiency virus type 1. J. Clin. Microbiol. 37:110-116. - PMC - PubMed
-
- Walter, E. A., B. Gilliam, J. A. Delmar, K. Spooner, J. T. Morris, N. Aronson, S. A. Wegner, N. L. Michael, and L. L. Jagodzinski. 2000. Clinical implications of identifying non-B subtypes of human immunodeficiency virus type 1 infection. Clin. Infect. Dis. 31:798-802. - PubMed
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources