Dual closed-loop, optoelectronic, auto-oscillatory detection circuit for monitoring fluorescence lifetime-based chemical sensors and biosensors
- PMID: 15189100
- DOI: 10.1117/1.1688814
Dual closed-loop, optoelectronic, auto-oscillatory detection circuit for monitoring fluorescence lifetime-based chemical sensors and biosensors
Abstract
We present a new detection instrument for sensor measurements based on excited-state fluorescence lifetimes. This system consists of a primary optoelectronic loop containing a resonance-type rf amplifier, a modulatable fluorescence-excitation light source, a fiber optic feedback loop (with a gap for a fluorescent sensor), and a photomultiplier tube. A secondary, phase-feedback optoelectronic circuit consists of a long-wavelength-pass optical filter, a second photomultiplier tube, a photodiode, an electronic phase detector, a dc amplifier, and an electronic phase shifter (inserted into the main loop). This phase-feedback circuit is new with respect to our previous work. Under the appropriate conditions, the main loop exhibits self-oscillations, manifesting themselves as sinusoidal rf modulation of light intensity. The phase-feedback circuit detects the modulation phase shift resulting from the finite excited-state lifetimes of a fluorophore. As the excited state lifetime changes, the phase shift from the electronic phase shifter also changes, which results in a shift in self-oscillation frequency. The detection system uses self-oscillation frequency as the detection parameter and has excellent resolution with respect to changes in excited-state lifetime ( approximately 1 ps). (c) 2004 Society of Photo-Optical Instrumentation Engineers.
Similar articles
-
Technique for detecting changes in fluorescence lifetime by means of optoelectronic circuit auto-oscillation.Opt Lett. 2001 Aug 15;26(16):1256-8. doi: 10.1364/ol.26.001256. Opt Lett. 2001. PMID: 18049578
-
Ultra sensitive sensor with enhanced dynamic range for high speed detection of multi-color fluorescence radiation.Biosens Bioelectron. 2008 May 15;23(10):1512-8. doi: 10.1016/j.bios.2008.01.015. Epub 2008 Jan 19. Biosens Bioelectron. 2008. PMID: 18304800
-
Optical imaging in microfluidic bioreactors enables oxygen monitoring for continuous cell culture.J Biomed Opt. 2006 Sep-Oct;11(5):050504. doi: 10.1117/1.2355665. J Biomed Opt. 2006. PMID: 17092147
-
Optical system design for biosensors based on CCD detection.Methods Mol Biol. 2009;503:239-58. doi: 10.1007/978-1-60327-567-5_13. Methods Mol Biol. 2009. PMID: 19151945 Review.
-
Photomultiplier tubes in biosensors.Methods Mol Biol. 2009;503:375-87. doi: 10.1007/978-1-60327-567-5_21. Methods Mol Biol. 2009. PMID: 19151953 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous