Reference values of fetal ductus venosus, inferior vena cava and hepatic vein blood flow velocities and waveform indices during the second and third trimester of pregnancy
- PMID: 15190437
- DOI: 10.1007/s00404-003-0586-6
Reference values of fetal ductus venosus, inferior vena cava and hepatic vein blood flow velocities and waveform indices during the second and third trimester of pregnancy
Abstract
Objective: Our objective was to establish reference values for ductus venosus, inferior vena cava and hepatic vein flow velocities during ventricular systole (S-wave) and diastole (D-wave), the lowest forward velocity during atrial contraction (a-wave), the intensity-weighted mean flow velocity (Vmean) and different calculated indices.
Methods: Venous flow velocity waveforms were obtained from 329 singleton pregnancies at 20-42 weeks of gestation by pulsed-wave color Doppler. Reference values were constructed by means of a quadratic regression model after logarithmic transformation of original data.
Results: With advancing gestational age the peak velocity index for the vein (PVIV) and pulsatility index for the vein (PIV) decreased whereas blood flow velocities increased. Blood flow velocities were highest in the ductus venosus and lowest in the right hepatic vein. Values for PVIV and PIV were highest in the hepatic vein and lowest in the ductus venosus. During atrial contraction there was a blood flow towards the fetal heart in the ductus venosus, whereas in the inferior vena cava and in the hepatic vein blood flow was either in the opposite from the fetal heart (reverse flow), or there was absent flow (zero flow) or flow was towards the fetal heart (positive flow).
Conclusions: The reference ranges and calculated velocities established in this study may be utilized in studies dealing with the role of ductus venosus and inferior vena cava blood flow in fetuses with chromosomal abnormalities or congenital heart disease as well as hypoxic conditions. We speculate, that the reduction in PVIV and PIV with advancing gestational age may reflect a decrease in cardiac afterload as a result of maturation of diastolic ventricular function.
Similar articles
-
Reference values of ductus venosus blood flow velocities and waveform indices from 10 to 20 weeks of gestation.Arch Gynecol Obstet. 2004 Mar;269(3):199-204. doi: 10.1007/s00404-003-0484-y. Epub 2003 Aug 21. Arch Gynecol Obstet. 2004. PMID: 12937920
-
Reference ranges for Doppler-assessed pulmonary venous blood flow velocities and pulsatility indices in normal human fetuses.Prenat Diagn. 2002 Sep;22(9):786-91. doi: 10.1002/pd.410. Prenat Diagn. 2002. PMID: 12224072
-
Flow velocity waveforms in the ductus venosus, umbilical vein and inferior vena cava in normal human fetuses at 12-15 weeks of gestation.Ultrasound Med Biol. 1993;19(6):441-5. doi: 10.1016/0301-5629(93)90120-d. Ultrasound Med Biol. 1993. PMID: 8236586
-
[Dopplersonography of the ductus venosus: assessment, evaluation and actual clinical importance].Z Geburtshilfe Neonatol. 2002 Jan-Feb;206(1):1-8. doi: 10.1055/s-2002-20943. Z Geburtshilfe Neonatol. 2002. PMID: 11887248 Review. German.
-
Coronary blood flow in fetuses with intrauterine growth restriction.J Perinat Med. 1998;26(3):143-56. J Perinat Med. 1998. PMID: 9773372 Review.
Cited by
-
Establishment of reference ranges for ductus venosus waveform indices in the Japanese population.J Med Ultrason (2001). 2010 Oct;37(4):201-7. doi: 10.1007/s10396-010-0269-4. Epub 2010 Jul 3. J Med Ultrason (2001). 2010. PMID: 27278195
-
Evaluation and Management of Fetal Cardiac Function and Heart Failure.Curr Treat Options Cardiovasc Med. 2016 Sep;18(9):55. doi: 10.1007/s11936-016-0477-3. Curr Treat Options Cardiovasc Med. 2016. PMID: 27423668 Review.
-
Z-Score Reference Ranges for Fetal Heart Functional Measurements in a Large Brazilian Pregnant Women Sample.Pediatr Cardiol. 2019 Mar;40(3):554-562. doi: 10.1007/s00246-018-2026-1. Epub 2018 Nov 10. Pediatr Cardiol. 2019. PMID: 30415382
-
Functional cardiac measurements performed by two-dimensional Doppler echocardiography in normal fetuses: Determination of Z-scores and future prospects.Ann Pediatr Cardiol. 2019 Sep-Dec;12(3):233-239. doi: 10.4103/apc.APC_173_18. Ann Pediatr Cardiol. 2019. PMID: 31516280 Free PMC article. Review.
-
The use of pulsed-wave Doppler in prenatal diagnosis. An update.J Prenat Med. 2007 Jan;1(1):23-5. J Prenat Med. 2007. PMID: 22470820 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources