Comparative Study
. 1992 Sep;23(9):1280-6.
doi: 10.1161/01.str.23.9.1280.

Evaluation of the vertebrobasilar-posterior system by transcranial color duplex sonography in adults

Affiliations
Comparative Study

Evaluation of the vertebrobasilar-posterior system by transcranial color duplex sonography in adults

M Schöning et al. Stroke. 1992 Sep.

Abstract

Background and purpose: The transcranial color duplex sonography technique was applied to the vertebrobasilar-posterior system to provide normal data for clinical application.

Methods: The intracranial posterior circulation was studied in 49 healthy volunteers (mean +/- SD age, 35 +/- 12 years) by a transcranial and suboccipital approach with a 2.0-MHz sector transducer of a computed sonography system.

Results: The posterior cerebral artery and the vertebrobasilar system were depicted clearly in the color Doppler mode. Pulsed Doppler signals could be recorded in the posterior cerebral (100%), basilar (92%), and vertebral arteries (89%). The following normal values were provided for all vessels: systolic peak, end-diastolic maximum, time-averaged, and time-averaged maximum velocities; resistance and pulsatility indexes; and a spectral broadening index. Mean +/- SD values were 45.9 +/- 9.6, 45.5 +/- 10.8, and 39.2 +/- 10.6 cm/sec for time-averaged maximum velocity, and 28.3 +/- 6.5, 30.6 +/- 7.2, and 24.7 +/- 8.4 cm/sec for time-averaged velocity in the posterior cerebral, basilar, and vertebral arteries, respectively. In a reproducibility study, duplex measurements of the posterior cerebral arteries were repeated in 27 subjects. The correlation between the two examiners was high (r = 0.56, p less than or equal to 0.0001 for time-averaged maximum velocity).

Conclusions: Color duplex sonography of the vertebrobasilar-posterior system is a new, noninvasive, bedside investigative technique. It permits visualization of artery flow in real time, relating these to adjacent brain and cranial structures, as well as angle-corrected duplex measurement of "true" flow velocities at defined sites of the vessels. Thus, it will open new diagnostic possibilities in disorders of the posterior circulation.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources