Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2004 Mar;21(3):287-301.
doi: 10.1080/02652030310001655498.

Migration from can coatings: Part 1. A size-exclusion chromatographic method for the simultaneous determination of overall migration and migrating substances below 1000 Da

Affiliations
Comparative Study

Migration from can coatings: Part 1. A size-exclusion chromatographic method for the simultaneous determination of overall migration and migrating substances below 1000 Da

A Schaefer et al. Food Addit Contam. 2004 Mar.

Abstract

The Council of Europe Resolution on coatings suggests a limit of 10 mg dm-2 for the sum of substances migrating into food simulants from an internal can coating. The Scientific Committee on Food differentiates the migrants into the substances with a molecular weight below 1000 Da, potentially being of toxicological concern, and the less toxicologically relevant species above 1000 Da. Hitherto, the determination of overall migration was based on a gravimetric method. A new method is described for the simultaneous determination of both overall migration and the migration of substances below 1000 Da based on separation by size exclusion chromatography (SEC) followed by ultraviolet detection (UVD) and evaporative light scattering detection (ELSD). The method is suitable for all volatile extraction media and simulants recommended by the European Union. For statistical comparison of both methods, the slightly modified reference method was validated in-house and extended to an additional gravimetric measurement of the migrants below 1000 Da. For the determination of the overall migration, both methods provided similar reproducibility (validated gravimetry: standard deviation (SD) = 0.16 mg dm-2; SEC-ELSD/UVD: SD = 0.12 mg dm-2) but significantly better results were obtained by the SEC-ELSD/UVD method. For migrating substances below 1000 Da, the gravimetric determination provides a poor sensitivity (limit of detection = 0.35 mg dm-2) compared with the SEC-ELSD/UVD method (limit of detection = 0.04 mg dm-2). The new method offers a lower limit of detection and higher precision as well as being less time consuming and easier to use.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources