Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1992 Aug;67(8):994-7.
doi: 10.1136/adc.67.8.994.

Optimum method for administration of biosynthetic human growth hormone: a randomised crossover trial of an Auto Injector and a pen injection system

Affiliations
Clinical Trial

Optimum method for administration of biosynthetic human growth hormone: a randomised crossover trial of an Auto Injector and a pen injection system

R Stanhope et al. Arch Dis Child. 1992 Aug.

Abstract

The use of optimum conventional growth hormone administration, using a growth hormone vial combined with an Auto Injector, was compared with a pen injection system using a cartridge of growth hormone. In both methods of administration the concentration of growth hormone was 16 IU/ml. Thirty patients (22 boys, eight girls) who had all previously been treated with growth hormone (4 IU/ml) administered using needles and syringes (without an Auto Injector) were randomised into receiving one of either treatment for three months and then crossed over for a further three months. Fourteen patients (10 boys, four girls) initially received KabiVial 16 IU/ml combined with an Auto Injector while 16 patients (12 boys, four girls) were treated with KabiPen 16 IU/ml. Mean age in both groups was 9.6 years. The majority of patients in both groups were treated with a regimen of either 15 or 20 units/m2/week as a daily subcutaneous injection. Of the 30 patients who started in this trial, two who commenced using an Auto Injector refused to change to a pen system and were excluded from further analysis. When scored on a scale of -5 to +5 general convenience when changing from an Auto Injector to the KabiPen decreased from +4.7 to +1.0. When assessed for pain, the Auto Injector group scored +4.7, which decreased to -0.2 (more painful) for the pen. At the end of the trial 23 patients (82%) chose to continue with the KabiVial/Auto Injector combination as they found this less painful and the child did not see the needle or need to insert the needle manually. Five patients (18%) continued with the KabiPen as they considered the device smaller and easier to use. The accuracy of dosing using KabiVial was 100% compared with the range of 88% to 111% using KabiPen as the latter was available only in 0.5 unit increments. No growth hormone was wasted using KabiVial, although a mean of 0.6 units was wasted with every 16 IU cartridge in the KabiPen system. It is concluded that patients should be able to contribute to the choice of growth hormone delivery systems and that newer methods need careful assessment.

PubMed Disclaimer

Comment in

References

    1. Horm Res. 1990;33 Suppl 4:83-9 - PubMed
    1. Acta Paediatr Scand Suppl. 1988;343:103-6 - PubMed
    1. Arch Dis Child. 1991 Dec;66(12):1466 - PubMed
    1. Arch Dis Child. 1991 Jun;66(6):686-8 - PubMed
    1. Arch Dis Child. 1988 May;63(5):491-4 - PubMed

Publication types

LinkOut - more resources