Detection of deep vein thrombosis with impedance plethysmography and real-time compression ultrasonography in hospitalized patients
- PMID: 1520059
Detection of deep vein thrombosis with impedance plethysmography and real-time compression ultrasonography in hospitalized patients
Abstract
Background: Serial testing with impedance plethysmography or compression ultrasonography has been demonstrated to be feasible and accurate for the detection of deep vein thrombosis (DVT) in symptomatic outpatients, and these techniques are replacing contrast venography in this patient category. Limited data, however, are available on the clinical utility of these noninvasive tests in symptomatic hospitalized patients. The objectives of our study were to determine the feasibility of ascending contrast venography and to evaluate the accuracy of these two noninvasive methods for the detection of DVT in symptomatic hospitalized patients.
Methods: A prospective, "blind" comparison of impedance plethysmography and compression ultrasonography with ascending contrast venography was performed in consecutive hospitalized patients with clinically suspected DVT of the leg.
Results: Of the 127 potentially eligible patients, 44 had to be excluded; 25 of these could not undergo venography (feasibility of venography, 80.3%). The sensitivity, specificity, and positive and negative predictive values of impedance plethysmography for proximal DVT were 96%, 83%, 82%, and 97%, respectively. For compression ultrasonography, these measures for proximal DVT were 97%, 86%, 87%, and 97%, respectively. The overall prevalence of DVT was 53%, of which 85% was located proximally.
Conclusions: Contrast venography cannot be performed in about 20% of consecutive symptomatic patients. Both impedance plethysmography and compression ultrasonography are feasible and valid alternatives to contrast venography in the diagnostic treatment of these patients.
Similar articles
-
Reevaluation of the sensitivity of impedance plethysmography for the detection of proximal deep vein thrombosis.Arch Intern Med. 1994 Sep 12;154(17):1930-3. Arch Intern Med. 1994. PMID: 8074596
-
Comparison of the accuracy of impedance plethysmography and compression ultrasonography in outpatients with clinically suspected deep vein thrombosis. A two centre paired-design prospective trial.Thromb Haemost. 1995 Dec;74(6):1423-7. Thromb Haemost. 1995. PMID: 8772213 Clinical Trial.
-
Compression ultrasonography as a reliable imaging monitor in deep venous thrombosis.Surg Gynecol Obstet. 1990 Sep;171(3):233-9. Surg Gynecol Obstet. 1990. PMID: 2201094
-
Measurement of the clinical and cost-effectiveness of non-invasive diagnostic testing strategies for deep vein thrombosis.Health Technol Assess. 2006 May;10(15):1-168, iii-iv. doi: 10.3310/hta10150. Health Technol Assess. 2006. PMID: 16707072 Review.
-
New developments in noninvasive diagnosis of deep vein thrombosis of the lower limbs.Ric Clin Lab. 1990 Jan-Mar;20(1):11-7. doi: 10.1007/BF02910144. Ric Clin Lab. 1990. PMID: 2192431 Review.
Cited by
-
Diagnostic accuracy of three ultrasonography strategies for deep vein thrombosis of the lower extremity: A systematic review and meta-analysis.PLoS One. 2020 Feb 11;15(2):e0228788. doi: 10.1371/journal.pone.0228788. eCollection 2020. PLoS One. 2020. PMID: 32045437 Free PMC article.
-
Meta-analysis of plethysmography and rheography in the diagnosis of deep vein thrombosis.Emerg Med J. 2006 Aug;23(8):630-5. doi: 10.1136/emj.2005.033381. Emerg Med J. 2006. PMID: 16858098 Free PMC article.
-
Predictors of a positive duplex scan in patients with a clinical presentation compatible with deep vein thrombosis or cellulitis.Can J Infect Dis. 2003 Jul;14(4):210-4. doi: 10.1155/2003/675682. Can J Infect Dis. 2003. PMID: 18159459 Free PMC article.
-
Cost-effectiveness of enoxaparin versus warfarin prophylaxis against deep-vein thrombosis after total hip replacement.CMAJ. 1994 Apr 1;150(7):1083-90. CMAJ. 1994. PMID: 8137188 Free PMC article.
-
Safety of withholding anticoagulation in pregnant women with suspected deep vein thrombosis following negative serial compression ultrasound and iliac vein imaging.CMAJ. 2013 Mar 5;185(4):E194-200. doi: 10.1503/cmaj.120895. Epub 2013 Jan 14. CMAJ. 2013. PMID: 23318405 Free PMC article. Clinical Trial.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical