Spectrophotometric determination of leukocytes in urine

Affiliations

Spectrophotometric determination of leukocytes in urine

Eda Imren-Eryilmaz et al. J Clin Lab Anal. 2004.

Abstract

A spectrophotometric method based on myeloperoxidase activity for the determination of leukocytes in urine is described. Red cells that may be found in urine samples were lysed by an ammonium chloride method. Leukocytes were then sedimented by centrifugation and lysed using Triton X-100 (Sigma Chemicals Co., St. Louis, MO). Myeloperoxidase-catalyzed oxidation of o-dianisidine was carried out at 37 degrees C, pH 7. The reaction was stopped with the addition of 2 M H2SO4, and a stable form of oxidized o-dianisidine in acidic solution was obtained. Solid particles that may be found in urine samples were removed by centrifugation to avoid turbidity, and absorbance values of the supernatants were recorded at 400 nm. An Average number of leukocytes were noted per number of fields by microscopic examination and were related with the absorbance values of the supernatants at 400 nm. Pearson correlation (r) between our presented spectrophotometric analysis results and visual microscopic analysis was 0.877. Roche Combur 10-test M strips (Roche, Mannheim, Germany) and Multistix 10 SG Bayer test strips (Bayer Diagnostics, UK) were 0.645 and 0.648, respectively (P < 0.0001).

PubMed Disclaimer

Similar articles

References

    1. Christenson RH, Tucker JA, Allen E. Results of dipstick tests, visual inspection, microscopic examination of urine sediment, and microbiological cultures of urine compared for simplifying urianalysis. Clin Chem 1985;31:448–450. - PubMed
    1. Gelbart SM, Chen WT, Reid R. Clinical trial of leukocyte test strips in routine use. Clin Chem 1983;29:997–999. - PubMed
    1. Penders J, Fiers T, Delanghe R. Quantitative evaluation of urinanalysis test strips. Clin Chem 2002;48:2236–2241. - PubMed
    1. Johnson GM, Schaeper R. Chromogenic lactate‐leukocyte esterase substrates. Bioconjug Chem 1997;8:76–80. - PubMed
    1. Skjold AC, Stover LR, Pendergrass JH, et al. New dip and read test for determining leukocytes in urine. Clin Chem 1987;33:1242–1245. - PubMed