Determination of a novel substance P inhibitor in human plasma by high-performance liquid chromatography with atmospheric pressure chemical ionization mass spectrometric detection using single and triple quadrupole detectors
- PMID: 15203036
- DOI: 10.1016/j.jchromb.2004.04.017
Determination of a novel substance P inhibitor in human plasma by high-performance liquid chromatography with atmospheric pressure chemical ionization mass spectrometric detection using single and triple quadrupole detectors
Abstract
Methods based on high-performance liquid chromatography (HPLC) with atmospheric-pressure chemical ionization (APCI) mass spectrometric (MS) detection using either single (MS) or triple (MS/MS) quadrupole mass spectrometric detection for the determination of (2R)-[1(R)-(3,5-bis-trifluoromethylphenyl)ethoxy]-3(S)-(4-fluoro-phenyl)morpholin-4-ylmethyl]-5-oxo-4,5-dihydro-[1,2,4]triazol)methyl morpholine (Aprepitant, Fig. 1) in human plasma has been developed. Aprepitant (I) and internal standard (II, Fig. 1) were isolated from the plasma matrix buffered to pH 9.8 using a liquid-liquid extraction with methyl-t-butyl ether (MTBE). The analytes were separated on a Keystone Scientific's Javelin BDS C-8 2 mm x 4.6 mm 3 microm guard column coupled to BDS C-8 50 mm x 4.6 mm 3 microm analytical column, utilizing a mobile phase of 50% acetonitrile and 50% water containing 0.1% formic acid and 10 mM ammonium acetate delivered at a flow rate of 1 ml/min. The single quadrupole instrument was operated in a single ion monitoring (SIM) mode analyzing the protonated molecules of Aprepitant and II at m/z 535 and 503, respectively. The triple quadrupole mass spectrometer was operated in multiple reaction monitoring mode (MRM) monitoring the precursor --> ion combinations of m/z 535 --> 277 and 503 --> 259 for Aprepitant and II, respectively. The linear calibration range for both single and triple quadrupole detectors was from 10 to 5000 ng/ml of plasma with coefficients of variation less than 8% at all concentrations. Both single and triple quadrupole instruments yielded similar precision and accuracy results. Matrix effect experiments performed on both instruments demonstrated the absence of any significant change in ionization of the analytes when comparing neat standards to analytes in the presence of plasma matrix. Both instruments were used successfully to support numerous clinical trials of Aprepitant.
Similar articles
-
Simultaneous determination of Aprepitant and two metabolites in human plasma by high-performance liquid chromatography with tandem mass spectrometric detection.J Pharm Biomed Anal. 2004 Sep 3;35(5):1213-29. doi: 10.1016/j.jpba.2004.03.020. J Pharm Biomed Anal. 2004. PMID: 15336366
-
Quantitative high-throughput determination of endogenous retinoids in human plasma using triple-stage liquid chromatography/tandem mass spectrometry.Rapid Commun Mass Spectrom. 2007;21(7):1176-86. doi: 10.1002/rcm.2946. Rapid Commun Mass Spectrom. 2007. PMID: 17330217
-
Assessment of the in-vivo stereochemical integrity of aprepitant based on the analysis of human plasma samples via high-performance liquid chromatography with mass spectrometric detection.Biomed Chromatogr. 2005 Sep;19(7):513-7. doi: 10.1002/bmc.472. Biomed Chromatogr. 2005. PMID: 15828059
-
Critical practical aspects in the application of liquid chromatography-mass spectrometric studies for the characterization of impurities and degradation products.J Pharm Biomed Anal. 2014 Jan;87:191-217. doi: 10.1016/j.jpba.2013.04.027. Epub 2013 Apr 28. J Pharm Biomed Anal. 2014. PMID: 23706957 Review.
-
New trends in the application of electron ionization to liquid chromatography-mass spectrometry interfacing.Mass Spectrom Rev. 2001 Mar-Apr;20(2):88-104. doi: 10.1002/mas.1004. Mass Spectrom Rev. 2001. PMID: 11455563 Review.
Cited by
-
Current literature in mass spectrometry.J Mass Spectrom. 2004 Nov;39(11):1383-94. doi: 10.1002/jms.712. J Mass Spectrom. 2004. PMID: 15532071 Free PMC article.
-
A sensitive and rapid liquid chromatography-tandem mass spectrometry method for the quantification of the novel neurokinin-1 receptor antagonist aprepitant in rhesus macaque plasma, and cerebral spinal fluid, and human plasma with application in translational NeuroAIDs research.J Pharm Biomed Anal. 2009 Apr 5;49(3):739-45. doi: 10.1016/j.jpba.2008.12.005. Epub 2008 Dec 13. J Pharm Biomed Anal. 2009. PMID: 19167182 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous