Migration from can coatings: part 2. Identification and quantification of migrating cyclic oligoesters below 1000 Da
- PMID: 15204562
- DOI: 10.1080/02652030310001637939
Migration from can coatings: part 2. Identification and quantification of migrating cyclic oligoesters below 1000 Da
Abstract
Metal cans for food use can be coated with lacquers based on polyester resins. Recent research has focussed on the identification and quantification of migrants released by coatings that are potentially absorbable (below 1000 Da). The presented method describes a procedure that was optimized to hydrolyse the polyester migrants into their monomers, polyvalent acids and polyols. The polyols were identified by gas chromatography with flame ionization detection GC-FID and the acids by high-performance liquid chromatography (HPLC) coupled with an ultraviolet and an electrospray ionization-mass selective detector (HPLC-ESI-MSD/UVD), respectively. With the knowledge of the polyester monomers, it was possible--at least tentatively--to identify the main components in the migrate as cyclic oligoesters by HPLC-ESI-MSD/UVD. A cyclic oligomer, CYCLO [3IPA (isophthalic acid) 3EG (ethylene glycol)] was synthesized and characterized by infrared, nuclear magnetic resonance and mass spectrometry as well as by elementary analysis for further confirmation. To determine the amount of migrating cyclic oligoesters, the response of the migrating substances was compared using different detectors, UVD, MSD and evaporative light scattering detector (ELSD). The response of the ELSD was dependent on the molecular weight of the analytes that reduced the accuracy of this detection type. The wavelength with the same absorption coefficient for IPA and terephthalic acid (TPA) was obtained at 232 nm. The UV(232nm) response of an oligoester is proportional to the number of its IPA/TPA moieties, which was verified for several TPA/IPA esters. The amount of the migrating oligoesters was determined using an UV(232nm) calibration of a commercially available TPA ester and the number of IPA/TPA moieties molecules gained from the ESI-MSD spectra. According to this method, the amount of migrating oligoesters below 1000 Da in the 95% ethanol migrate varied from 0.1 to 0.6 mg dm(-2) (0.6-3.6 mg kg(-1) food) in the examined coatings. The determined amounts account for about 50% of the total migrate below 1000 Da.
Similar articles
-
Migration from can coatings: part 3. Synthesis, identification and quantification of migrating epoxy-based substances below 1000 Da.Food Addit Contam. 2004 Apr;21(4):390-405. doi: 10.1080/02652030310001657388. Food Addit Contam. 2004. PMID: 15204563
-
Migration from can coatings: Part 1. A size-exclusion chromatographic method for the simultaneous determination of overall migration and migrating substances below 1000 Da.Food Addit Contam. 2004 Mar;21(3):287-301. doi: 10.1080/02652030310001655498. Food Addit Contam. 2004. PMID: 15195475
-
Identification of unknown compounds from polyester cans coatings that may potentially migrate into food or food simulants.J Chromatogr A. 2016 Apr 29;1444:106-13. doi: 10.1016/j.chroma.2016.03.038. Epub 2016 Mar 16. J Chromatogr A. 2016. PMID: 27018189
-
Comprehensive analysis of migrates from food-packaging materials: a challenge.Food Addit Contam. 2002;19 Suppl:185-91. doi: 10.1080/02652030110072713. Food Addit Contam. 2002. PMID: 11962707 Review.
-
On-line coupled high performance liquid chromatography-gas chromatography for the analysis of contamination by mineral oil. Part 2: migration from paperboard into dry foods: interpretation of chromatograms.J Chromatogr A. 2012 Sep 14;1255:76-99. doi: 10.1016/j.chroma.2012.05.096. Epub 2012 Jun 6. J Chromatogr A. 2012. PMID: 22727555 Review.
Cited by
-
Identification and Quantitation Studies of Migrants from BPA Alternative Food-Contact Metal Can Coatings.Polymers (Basel). 2020 Nov 29;12(12):2846. doi: 10.3390/polym12122846. Polymers (Basel). 2020. PMID: 33260375 Free PMC article.
-
Oligoester Identification in the Inner Coatings of Metallic Cans by High-Pressure Liquid Chromatography-Mass Spectrometry with Cone Voltage-Induced Fragmentation.Materials (Basel). 2024 Jun 6;17(11):2771. doi: 10.3390/ma17112771. Materials (Basel). 2024. PMID: 38894033 Free PMC article.
-
Mass Spectrometry of Polyurethanes.Polymer (Guildf). 2019 Oct 24;181:121624. doi: 10.1016/j.polymer.2019.121624. Epub 2019 Jul 2. Polymer (Guildf). 2019. PMID: 32831406 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous