Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004 Apr;21(4):390-405.
doi: 10.1080/02652030310001657388.

Migration from can coatings: part 3. Synthesis, identification and quantification of migrating epoxy-based substances below 1000 Da

Affiliations

Migration from can coatings: part 3. Synthesis, identification and quantification of migrating epoxy-based substances below 1000 Da

A Schaefer et al. Food Addit Contam. 2004 Apr.

Abstract

Bisphenol A-derived glycidyl ethers as well as its reaction products with other lacquer components can migrate into the packed food from epoxy-based can coatings. A sensitive and selective method is presented using high-performance liquid chromatography coupled with ultraviolet light, fluorescence and electrospray ionization-mass selective detection for the identification and quantification of all migrants with a bisphenol A backbone and a molecular weight below 1000 Da, an estimated boundary for the absorption in the gastrointestinal tract. The identification of migrants was confirmed by microreactions of technical bisphenol A diglycidyl ether with solvents and phenols, which provided the fragmentation pattern of the mass selective detection and relative retentions of 42 different bisphenol A-related substances. It was shown by calibration of different isolated and synthesized bisphenol A derivatives that the fluorescence response relies on the amount of bisphenol A moiety in the respective molecule. Therefore, all migrating bisphenol A-related substances below 1000 Da were determined as bisphenol A diglycidyl ether equivalents using a calibration (fluorescence detection) of the commercially available bisphenol A diglycidyl ether monomer. The limit of quantification was set at 5 microg bisphenol A diglycidyl ether equivalents kg(-1) (or 0.8 microg dm(-2)). This method was validated for epoxy coatings (0.1 microg dm(-2) limit of detection and 24 microg bisphenol A-related substances below 1000 Da dm(-2) standard deviation, corresponding to 4.4% relative standard deviation). The quantification could be extended by combining the fluorescence response and structural information gained from the mass spectra, which provides more accurate results for each migrant. The calculation is based on the calibration of the bisphenol A chromophore content of the molecule. According to this method, the amount of migrating bisphenol A-related substances below 1000 Da in the acetonitrile extract (assuming a worst case) varied from about 0.4 to 0.7 mg dm(-2) in the examined coatings. The determined amounts comply with about 50% of the total migrate below 1000 Da.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources