Performance of small evacuated canisters equipped with a novel flow controller for the collection of personal air samples
- PMID: 15204875
- DOI: 10.1080/15459620490424483
Performance of small evacuated canisters equipped with a novel flow controller for the collection of personal air samples
Abstract
Small evacuated canisters have become more common in industrial hygiene personal sampling in recent years. The smaller canisters necessitate a low flow rate to ensure a full-shift air sample can be collected. Evaluation of small evacuated canisters compared to sorbent sampling methods is essential to ensure that the canisters accurately monitor airborne contamination. This data, in a controlled environment, will provide practitioners with valuable reference information when considering air-sampling campaigns. Six 300-mL evacuated canisters were used to collect 6-hour breathing zone samples of styrene on volunteers in a large exposure chamber. The canisters were specially designed with a capillary flow controller developed at McGill University in the mid-1990s. Based on the geometry of the capillary the airflow into the canisters was controlled to a low flow rate, approximately 0.3 mL/min. This low sampling flow rate allowed for the use of small-volume canisters as personal samplers to collect styrene vapors. Charcoal tubes and diffusive badges were simultaneously used to collect side-by-side samples for comparison. In addition, an online gas chromatograph (GC) documented the concentration in the chamber throughout the duration of the exposure. The three methods did not disclose any significant statistical difference when compared to the online GC values and to each other. In addition, linear regression analysis between the charcoal tubes and the canisters resulted in a correlation (R(2) > 0.95). An evaluation of the bias and precision (overall uncertainty) of the capillary-canister method, charcoal tubes, and diffusive badges found them to be within criteria established by European Committee for Standardization 482. The results indicate that the capillary-canister sampling device can be an acceptable alternative to sorbent samplers as a personal sampler providing reliable results that are representative of exposures.
Similar articles
-
A novel personal air sampling device for collecting volatile organic compounds: a comparison to charcoal tubes and diffusive badges.J Occup Environ Hyg. 2004 Feb;1(2):69-81. doi: 10.1080/15459620490275542. J Occup Environ Hyg. 2004. PMID: 15204881
-
A field study to assess the long-term sampling feasibility of evacuated canisters and the development of a mathematical model to analyze potential sampling bias.J Occup Environ Hyg. 2005 Sep;2(9):474-80. doi: 10.1080/15459620500252779. J Occup Environ Hyg. 2005. PMID: 16105798
-
Development of a flow controller for long-term sampling of gases and vapors using evacuated canisters.Environ Sci Technol. 2002 Nov 15;36(22):4912-20. doi: 10.1021/es025708n. Environ Sci Technol. 2002. PMID: 12487317
-
Sorbent-based sampling methods for volatile and semi-volatile organic compounds in air Part 1: Sorbent-based air monitoring options.J Chromatogr A. 2010 Apr 16;1217(16):2674-84. doi: 10.1016/j.chroma.2009.12.042. Epub 2010 Jan 11. J Chromatogr A. 2010. PMID: 20106481 Review.
-
Sorbent-based sampling methods for volatile and semi-volatile organic compounds in air. Part 2. Sorbent selection and other aspects of optimizing air monitoring methods.J Chromatogr A. 2010 Apr 16;1217(16):2685-94. doi: 10.1016/j.chroma.2010.01.015. Epub 2010 Jan 14. J Chromatogr A. 2010. PMID: 20106482 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous