Electron microscopy of wet tissues: a case study in renal pathology
- PMID: 15204979
- DOI: 10.1080/01926230490431772
Electron microscopy of wet tissues: a case study in renal pathology
Abstract
In this report we introduce wet-tissue scanning electron microscopy, a novel technique for direct imaging of wet tissue samples using backscattered electrons. Samples placed in sealed capsules are imaged through a resilient, electron-transparent membrane. The contrast of the imaged samples may be enhanced by chemical staining. The samples several millimeters thick and imaged without sectioning, makes this technique suitable for rapid analysis of tissue specimens. We applied this technique to D-limonene-induced nephropathy where accumulation of hyaline protein droplets is induced in proximal and distal convoluted tubules of the kidney. Images obtained by scanning electron microscopy of hydrated kidney specimens exhibited superior resolution, contrast, and magnification compared with those obtained by conventional light microscopy of paraffin sections. The electron micrographs can be obtained within an hour of tissue removal, whereas preparation for light microscopy requires at least 1 day. These advantages of the wet scanning electron microscopy technique indicate its potential utility in a wide range of applications in histopathology and toxicology.
Similar articles
-
Scanning electron microscopy of cells and tissues under fully hydrated conditions.Proc Natl Acad Sci U S A. 2004 Mar 9;101(10):3346-51. doi: 10.1073/pnas.0400088101. Epub 2004 Feb 26. Proc Natl Acad Sci U S A. 2004. PMID: 14988502 Free PMC article.
-
A novel method for "Wet" SEM.Ultrastruct Pathol. 2004 Jan-Feb;28(1):29-31. Ultrastruct Pathol. 2004. PMID: 14967596
-
Application of low-vacuum scanning electron microscopy for renal biopsy specimens.Pathol Res Pract. 2012 Sep 15;208(9):503-9. doi: 10.1016/j.prp.2012.05.006. Epub 2012 Jul 15. Pathol Res Pract. 2012. PMID: 22795691
-
Conventional and high resolution scanning electron microscopy of biological sectioned material.Scanning Microsc. 1991 Mar;5(1):135-44; discussion 144-5. Scanning Microsc. 1991. PMID: 2052919 Review.
-
Scanning electron microscopy of bone: instrument, specimen, and issues.Microsc Res Tech. 1996 Feb 1;33(2):92-120. doi: 10.1002/(SICI)1097-0029(19960201)33:2<92::AID-JEMT2>3.0.CO;2-0. Microsc Res Tech. 1996. PMID: 8845522 Review.
Cited by
-
Nail Damage (Severe Onychodystrophy) Induced by Acrylate Glue: Scanning Electron Microscopy and Energy Dispersive X-Ray Investigations.Skin Appendage Disord. 2017 Jan;2(3-4):137-142. doi: 10.1159/000450791. Epub 2016 Oct 11. Skin Appendage Disord. 2017. PMID: 28232921 Free PMC article.
-
Observation of tissues in open aqueous solution by atmospheric scanning electron microscopy: applicability to intraoperative cancer diagnosis.Int J Oncol. 2015 May;46(5):1872-82. doi: 10.3892/ijo.2015.2905. Epub 2015 Feb 24. Int J Oncol. 2015. PMID: 25707365 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical