Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2004 Jul;25(7):743-7.
doi: 10.1097/01.mnm.0000131133.07279.60.

Technetium-99m-L,L-ethylenedicysteine renal scan as a single-modality investigation for the evaluation of renal morphology and function: a comparative study with technetium-99m-dimercaptosuccinic acid

Affiliations
Clinical Trial

Technetium-99m-L,L-ethylenedicysteine renal scan as a single-modality investigation for the evaluation of renal morphology and function: a comparative study with technetium-99m-dimercaptosuccinic acid

Chandrashekar Narayana et al. Nucl Med Commun. 2004 Jul.

Abstract

Aim: To evaluate whether cortical scars can be detected using the summed images of technetium-99m-L,L-ethylenedicysteine (99mTc-L,L-EC) renal dynamic scan, and to compare the results with technetium-99m-dimercaptosuccinic acid (99mTc-DMSA) scan. To evaluate the inter-observer variability for 99mTc-L,L-EC and 99mTc-DMSA scan reporting.

Methods: One hundred and three patients were initially included in the study; 21 were excluded, five due to a single functioning kidney and 16 due to impaired renal function (serum creatinine>2.5 mg.dl(-1)). Eighty-two patients (39 females, 43 males), including 31 children, with a mean age of 33.4+/-11.3 years (range, 4 months to 74 years), underwent both 99mTc-DMSA and 99mTc-L,L-EC scintigraphy within a period of 14 days. 99mTc-L,L-EC images were regrouped into 2 min image sets, and the initial 2 min summed image (cortical phase) was used for the evaluation of scars. Three independent observers analysed both images separately on different days without being aware of the identity and clinical details of the patients. Their 99mTc-L,L-EC findings were compared with the consensus 99mTc-DMSA scan findings taken as reference.

Results: The overall sensitivity of 99mTc-L,L-EC scans was 93% and the specificity was 96%. The inter-observer variability was 0.91 for 99mTc-L,L-EC and 0.94 for 99mTc-DMSA scan reporting, using the weighted kappa analysis at P<0.05.

Conclusions: 99mTc-L,L-EC is an excellent single-modality comprehensive investigational agent for renal morphology, function and outflow tract evaluation with the added advantages of lower cost, convenience and low radiation exposure to the patient.