Evaluation of gloss changes of two denture acrylic resin materials in four different beverages
- PMID: 15209229
- DOI: 10.1016/S0109-5641(03)00099-X
Evaluation of gloss changes of two denture acrylic resin materials in four different beverages
Abstract
Objectives: The primary disadvantages of the materials which are used in construction of complete and removable partial dentures is that their esthetic, physical and mechanical properties change rapidly with time in the oral environment. For esthetics, color stability is one of the criteria that needs careful attention. Color may provide important information on the serviceability of these materials. Color change affects the gloss of these materials. The objective of the present study was to determine the gloss changes resulting from the testing process in four different beverages in one heat-polymerized denture base resin and one cold-polymerized denture base repair resin.
Methods: Thirty-six samples were fabricated for each material. Each sample had a smooth polished and a rough unpolished surface. The gloss measurements were made with a glossmeter before testing. Four different beverages (tea, coffee, cola and cherry juice) were used for testing. Two angles of illumination (20 and 60 degrees) were used for the gloss measurements. The samples were immersed in water, tea, coffee, cola and cherry juice solutions. The gloss of the samples was measured again with the glossmeter at the end of the 45th day and 135th day of testing. The arithmetic mean and standard deviation of each of the samples were calculated and compared with each other statistically by using the Wilcoxon test (within times) (p < or = 0.05 significant), the Kruskal-Wallis analysis of variance (p < or = 0.05 significant) and the Mann-Whitney U-test with Bonforoni correction (when the difference between the samples was significant) (p < or = 0.05 significant).
Results: The results of this study revealed that gloss changes occurred after testing in heat-polymerized denture base resin and cold-polymerized denture base repair resin. The significance of the gloss changes exhibited by each sample, kept for different lengths of time in the same solution, were compared using the Wilcoxon test. The results were statistically significant (p < or = 0.05). According to the Kruskal-Wallis analysis of variance, the difference between measurements for angles of illumination was statistically significant (p < or = 0.05). Also according to the Mann-Whitney U-test, the difference between two polished surfaces or two unpolished surfaces was statistically insignificant (p > 0.05), but the difference between smooth polished and rough unpolished surfaces was statistically significant (p < or = 0.05).
Significance: It was found that either the gloss of heat-polymerized denture base resin or the gloss of cold-polymerized denture base repair resin was affected by tested agents, and the four beverages demonstrated noticeable gloss changes. Cherry juice demonstrated the least change, while tea exhibited the greatest change.
Similar articles
-
Effects of different drinks on stainability of resin composite provisional restorative materials.J Prosthet Dent. 2005 Aug;94(2):118-24. doi: 10.1016/j.prosdent.2005.05.004. J Prosthet Dent. 2005. PMID: 16046965
-
Color stability of denture acrylic resins and a soft lining material against tea, coffee, and nicotine.J Prosthodont. 2010 Feb;19(2):118-24. doi: 10.1111/j.1532-849X.2009.00535.x. Epub 2009 Dec 3. J Prosthodont. 2010. PMID: 20002978
-
The effect of polymerization cycles on color stability of microwave-processed denture base resin.J Prosthodont. 2009 Jul;18(5):432-7. doi: 10.1111/j.1532-849X.2009.00458.x. Epub 2009 Apr 3. J Prosthodont. 2009. PMID: 19374705
-
Denture base resins: comparison study of color stability.J Prosthet Dent. 1992 Jul;68(1):78-82. doi: 10.1016/0022-3913(92)90290-q. J Prosthet Dent. 1992. PMID: 1403926 Review.
-
Denture base acrylic resins: friend or foe?Compendium. 1990 Dec;11(12):720-5. Compendium. 1990. PMID: 2088619 Review.
Cited by
-
Surface roughness implant-retained mandibular bar and ball joint overdentures and adherence of microorganisms.Eur J Dent. 2018 Oct-Dec;12(4):546-552. doi: 10.4103/ejd.ejd_265_18. Eur J Dent. 2018. PMID: 30369801 Free PMC article.
-
Color changes of three different brands of acrylic teeth in removable dentures in three different beverages: An in vitro study.J Dent Res Dent Clin Dent Prospects. 2020 Summer;14(3):159-165. doi: 10.34172/joddd.2020.034. Epub 2020 Sep 21. J Dent Res Dent Clin Dent Prospects. 2020. PMID: 33408820 Free PMC article.
-
Effects of thermocycling and various drinks on the color stability of heat-polymerized acrylic resin.J Istanb Univ Fac Dent. 2016 Oct 1;50(3):15-20. doi: 10.17096/jiufd.28587. eCollection 2016. J Istanb Univ Fac Dent. 2016. PMID: 28955571 Free PMC article.
-
Colour Stability of Various Types of Acrylic Teeth Exposed to Coffee, Tea and Cola.J Dent Biomater. 2016 Dec;3(4):335-340. J Dent Biomater. 2016. PMID: 28959762 Free PMC article.
-
Comparative evaluation of color change between two types of acrylic resin and flexible resin after thermo cycling. An in vitro study.J Indian Prosthodont Soc. 2013 Sep;13(3):327-37. doi: 10.1007/s13191-013-0289-z. Epub 2013 May 5. J Indian Prosthodont Soc. 2013. PMID: 24431755 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical