Prediction of the clinical performance of adult arterial cannulas
- PMID: 15209859
- DOI: 10.1111/j.1525-1594.2004.07373.x
Prediction of the clinical performance of adult arterial cannulas
Abstract
The choice of an arterial cannula for cardiac surgery is often difficult. The clinician has to rely on the pressure-flow diagrams provided by the manufacturer that are all produced using water. The conversion of these water data to representative clinical conditions is often difficult if not impossible. In this in vivo study the theory of dynamic similarity is applied to scale the manufacturer's data to the clinical situation, in order to predict the pressure drop desired by the cardiac surgeon. Three hundred and forty-seven samples of pressure drop are obtained in 58 patients. Patients are grouped according to cannula size (20, 22, and 24 Fr). Very good correlation is found between measured and predicted values (r = 0.93; 0.86; 0.87 for 20; 22; 24 Fr). As a result, windows of optimal performance are constructed for each cannula diameter. This technique also allows the construction of an online recommendation for signaling abnormal cannula performance during cardiac surgery.
Similar articles
-
Performance prediction of a percutaneous ventricular assist system using nonlinear circuit analysis techniques.IEEE Trans Biomed Eng. 2008 Feb;55(2 Pt 1):419-29. doi: 10.1109/TBME.2007.908092. IEEE Trans Biomed Eng. 2008. PMID: 18269977
-
A performance evaluation of eight geometrically different 10 Fr pediatric arterial cannulae under pulsatile and nonpulsatile perfusion conditions in an infant cardiopulmonary bypass model.ASAIO J. 2008 May-Jun;54(3):306-15. doi: 10.1097/MAT.0b013e3181744071. ASAIO J. 2008. PMID: 18496282
-
Funnel-tipped aortic cannula for reduction of atheroemboli.Ann Thorac Surg. 2009 Aug;88(2):551-7. doi: 10.1016/j.athoracsur.2009.04.108. Ann Thorac Surg. 2009. PMID: 19632411
-
Intravascular ultrasonic assessment of stent diameters derived from manufacturer's compliance charts.Am J Cardiol. 2005 Jul 1;96(1):74-8. doi: 10.1016/j.amjcard.2005.02.049. Am J Cardiol. 2005. PMID: 15979438
-
[Cardiovascular risk stratification. Systolic, diastolic or pulse pressure?].Ital Heart J Suppl. 2001 Apr;2(4):356-8. Ital Heart J Suppl. 2001. PMID: 19397006 Review. Italian.
Cited by
-
Clinical assessment of cannula performance during adult minimally invasive valve surgery using predictive mathematical models.Interdiscip Cardiovasc Thorac Surg. 2025 Jun 4;40(6):ivaf127. doi: 10.1093/icvts/ivaf127. Interdiscip Cardiovasc Thorac Surg. 2025. PMID: 40442945 Free PMC article.
-
Optimization of the perfusion circuit and its possible impact on the inflammatory response.J Extra Corpor Technol. 2007 Dec;39(4):285-8. J Extra Corpor Technol. 2007. PMID: 18293821 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials