Comparative Study
. 2004 Jul;240(1):187-92.
doi: 10.1097/01.sla.0000130726.03886.93.

Choice of anesthesia and risk of reoperation for recurrence in groin hernia repair

Affiliations
Comparative Study

Choice of anesthesia and risk of reoperation for recurrence in groin hernia repair

Pär Nordin et al. Ann Surg. 2004 Jul.

Abstract

Objective: To analyze the relative risk of reoperation for recurrence using 3 anesthetic alternatives, general anesthesia (GA), regional (spinal-, epidural-) anesthesia (RA), and local anesthesia (LA), and to study time trends for various anesthetic and operative methods, as well as other risk factors regarding reoperation for recurrence.

Background: The method of anesthesia used for hernia repair is generally assumed not to affect the long-term outcome. The few studies on the topic have rendered conflicting results.

Methods: Data from the Swedish Hernia Register was used. Relative risk was first estimated using univariate analysis for assumed risk variables and then selecting variables with the highest or lowest univariate risk for multivariate analysis.

Results: From 1992 through 2001, 59,823 hernia repairs were recorded. Despite the fact that univariate analysis showed a somewhat lower risk for reoperation in the LA group, the multivariate analysis showed that LA was associated with a significantly increased risk for reoperation in primary but not in recurrent hernia repair. The Lichtenstein technique carried a significantly lower reoperation risk than any other method of operation.

Conclusions: LA was associated with a higher risk of reoperation for recurrence after primary hernia repair. The use of mesh techniques has increased considerably, and among these the Lichtenstein repair was associated with a significantly lower risk for reoperation than any other repair.

PubMed Disclaimer

Figures

None
FIGURE 1. Choice of anesthesia in the SHR between 1992 and 2001 (59,823 hernia repairs).
None
FIGURE 2. Day-case surgery in the SHR, 1992 to 2001 (n = 59,823).
None
FIGURE 3. Number of hernias and percentage of recurrent hernias in SHR between 1992 and 2001.
None
FIGURE 4. Methods of repair in SHR between 1992 and 2001 (59,823).

Similar articles

Cited by

References

    1. Cushing H. The employment of local anaesthetics in the radical cure of certain cases of hernia with a note on the nervous anatomy of the inguinal region. Ann Surg. 1900;31:1. - PMC - PubMed
    1. Amid PK, Shulman AG, Lichtenstein IL. Open tension-free repair of inguinal hernias: the Lichenstein technique. Eur J Surg. 1996;162:447–453. - PubMed
    1. Bendavid R. Symposium on the management of inguinal hernias. 4. The Shouldice technique: a canon in hernia repair. Can J Surg. 1997;40:199–207. - PMC - PubMed
    1. Callesen T, Bech K, Kehlet H. One thousand consecutive inguinal hernia repairs under unmonitored local anaesthesia. Anesth Analg. 2001;93:1373–1376. - PubMed
    1. Kark AE, Kurzer MN, Belsham PA. Three thousand one hundred seventy-five primary inguinal hernia repairs: advantage of ambulatory open mesh repair in local anaesthesia. Am Coll Surg. 1998;186:447–455. - PubMed

Publication types