CyberKnife frameless stereotactic radiosurgery for spinal lesions: clinical experience in 125 cases
- PMID: 15214977
CyberKnife frameless stereotactic radiosurgery for spinal lesions: clinical experience in 125 cases
Abstract
Objective: The role of stereotactic radiosurgery for the treatment of intracranial lesions is well established. Its use for the treatment of spinal lesions has been limited by the availability of effective target-immobilizing devices. Conventional external beam radiotherapy lacks the precision to allow delivery of large doses of radiation near radiosensitive structures such as the spinal cord. The CyberKnife (Accuray, Inc., Sunnyvale, CA) is an image-guided frameless stereotactic radiosurgery system that allows for the radiosurgical treatment of spinal lesions. This study evaluated the feasibility and effectiveness of the treatment of spinal lesions with a single-fraction radiosurgical technique using the CyberKnife.
Methods: The CyberKnife system uses the coupling of an orthogonal pair of x-ray cameras to a dynamically manipulated robot-mounted linear accelerator with six degrees of freedom that guides the therapy beam to the intended target without the use of frame-based fixation. Real-time imaging allows the tracking of patient movement. Cervical spine lesions were located and tracked relative to cranial bony landmarks; lower spinal lesions were tracked relative to fiducial bone markers. In this prospective cohort evaluation of a spine radiosurgery technique, 125 spinal lesions in 115 consecutive patients were treated with a single-fraction radiosurgery technique (45 cervical, 30 thoracic, 36 lumbar, and 14 sacral). There were 17 benign tumors and 108 metastatic lesions. All dose plans were calculated on the basis of computed tomographic images acquired from 1.25-mm slices with an inverse treatment planning technique. Radiosurgical circular cones ranging in diameter from 5 to 40 mm were used.
Results: Tumor volume ranged from 0.3 to 232 cm(3) (mean, 27.8 cm(3)). Seventy-eight lesions had received external beam irradiation previously. Tumor dose was maintained at 12 to 20 Gy to the 80% isodose line (mean, 14 Gy); canal volume receiving more than 8 Gy ranged from 0.0 to 1.7 cm(3) (mean, 0.2 cm(3)). No acute radiation toxicity or new neurological deficits occurred during the follow-up period (range, 9-30 mo; median, 18 mo). Axial and radicular pain improved in 74 of 79 patients who were symptomatic before treatment.
Conclusion: This is the first large prospective evaluation of this frameless image-guided spinal radiosurgery system. The CyberKnife system was found to be feasible, safe, and effective. The major potential benefits of radiosurgical ablation of spinal lesions are short treatment time in an outpatient setting with rapid recovery and symptomatic response. This technique offers a successful therapeutic modality for the treatment of a variety of spinal lesions as a primary treatment or for lesions not amenable to open surgical techniques, in medically inoperable patients, in lesions located in previously irradiated sites, or as an adjunct to surgery.
Similar articles
-
Clinical assessment of stereotactic IGRT: spinal radiosurgery.Med Dosim. 2008 Summer;33(2):107-16. doi: 10.1016/j.meddos.2008.02.003. Epub 2008 Mar 31. Med Dosim. 2008. PMID: 18456162
-
Feasibility of frameless single-fraction stereotactic radiosurgery for spinal lesions.Neurosurg Focus. 2002 Oct 15;13(4):e2. doi: 10.3171/foc.2002.13.4.3. Neurosurg Focus. 2002. PMID: 15771401
-
CyberKnife frameless single-fraction stereotactic radiosurgery for benign tumors of the spine.Neurosurg Focus. 2003 May 15;14(5):e16. doi: 10.3171/foc.2003.14.5.17. Neurosurg Focus. 2003. PMID: 15669812
-
Cyberknife radiosurgery for metastatic spine tumors.Neurosurg Clin N Am. 2004 Oct;15(4):491-501. doi: 10.1016/j.nec.2004.04.013. Neurosurg Clin N Am. 2004. PMID: 15450884 Review.
-
CyberKnife radiosurgery for spinal neoplasms.Prog Neurol Surg. 2007;20:340-358. doi: 10.1159/000100177. Prog Neurol Surg. 2007. PMID: 17318002 Review.
Cited by
-
Cyberknife: A double edged sword?Rep Pract Oncol Radiother. 2010 Jul 6;15(4):93-7. doi: 10.1016/j.rpor.2010.05.002. Rep Pract Oncol Radiother. 2010. PMID: 24376931 Free PMC article. Review.
-
Normal tissue toxicity after small field hypofractionated stereotactic body radiation.Radiat Oncol. 2008 Oct 31;3:36. doi: 10.1186/1748-717X-3-36. Radiat Oncol. 2008. PMID: 18976463 Free PMC article. Review.
-
Initial Experience With 6D Skull Tracking and Intrafractional Motion Monitoring in the United Arab Emirates' First CyberKnife® Radiosurgery Center.Cureus. 2024 Jan 11;16(1):e52143. doi: 10.7759/cureus.52143. eCollection 2024 Jan. Cureus. 2024. PMID: 38222986 Free PMC article.
-
New frontiers in radiosurgery for the brain and body.Proc (Bayl Univ Med Cent). 2005 Oct;18(4):311-9; discussion 319-20. doi: 10.1080/08998280.2005.11928087. Proc (Bayl Univ Med Cent). 2005. PMID: 16252020 Free PMC article.
-
Management and outcome in adult intramedullary spinal cord tumours: a 20-year single institution experience.BMC Res Notes. 2014 Dec 15;7:908. doi: 10.1186/1756-0500-7-908. BMC Res Notes. 2014. PMID: 25495874 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical