Comparative Study
. 1992 Sep-Oct;16(5):731-6.
doi: 10.1097/00004728-199209000-00012.

Volume T1-weighted gradient echo MRI in multiple sclerosis patients

Affiliations
Comparative Study

Volume T1-weighted gradient echo MRI in multiple sclerosis patients

M Shah et al. J Comput Assist Tomogr. 1992 Sep-Oct.

Abstract

Three-dimensional (3D) volume turbo fast low angle shot (FLASH) techniques have become available which produce heavily T1-weighted images, similar to inversion recovery scans, utilizing the appropriate flip angle and inversion time. The purpose of this study was to compare the sensitivity of a rapid volume gradient echo technique [3D magnetization prepared rapid acquisition gradient echo (MP RAGE)] in identifying multiple sclerosis (MS) plaques with a conventional T2-weighted spin echo (SE) sequence. Ten patients with clinical MS were evaluated. Patients underwent a routine examination consisting of an axial T2-weighted SE sequence (2,500,22/90) and a coronal 3D MP RAGE, 10/4/10, acquired as 128 two mm partitions. In six patients, area measurements of 22 plaques were determined on both the axial T2-weighted SE examinations and the axial reformatted MP RAGE examinations. The overall number of plaques utilizing each technique was approximately the same. One hundred twenty-two plaques were visualized for the 3D MP RAGE sequence, and 128 plaques for the T2-weighted SE sequence. There were differences in detection of plaques in different regions, with plaques in gray matter better demonstrated utilizing the conventional T2-weighted SE sequence. Plaques in the corpus callosum, pons, and brachia pontis were better demonstrated utilizing 3D MP RAGE. No significant difference was found between the areas measured on the MP RAGE sequence and on the T2-weighted SE sequence. Three-dimensional MP RAGE provides a sensitive and complementary method to conventional T2-weighted SE sequences in the evaluation of patients with MS.

PubMed Disclaimer

Publication types

LinkOut - more resources